11
80-0180-339, Rev 2
Descriptions, Part Numbers, and Measurements
Parts, Part Numbers, and Locations
The following are the parts, part numbers, and locations:
Parts
Part Number
Location
PS-SE Circuit Board
A29-0623-02
Power Supply
Battery Backup System Kit
BBK-SE
Power Supply
Exit Device SE Control Board
91-0035
Exit Device
NOTE:
The following fuses can be ordered from Fuses Unlimited
at 1-800-255-1919.
Fuse F1 (2A, Slow Blow)
0213002.MXP
Power Supply
Fuse F2 (2A, Slow Blow)
0213002.MXP
Power Supply
Fuse F3 (unserviceable, Slow Blow)
0230004.HXP
Power Supply
PS-SE Value Readings
OUT1 and OUT2 when IN1 and IN2 are open:
1.6 VDC
OUT1 and OUT2 when IN1 and IN2 are closed: 24 VDC (unregulated)
LED Configuration
NOTE:
If OUT1 and/or OUT2 are on and IN1 and IN2 are open, the
board will need to be replaced.
Power to PS-SE board: Main Power LED (Red) and Output Power LED
(Green) are on.
Frequently Asked Questions
The
exit device won’t unlock when I use my access control system.
1. ENSURE PS-SE board that MAIN POWER and OUTPUT POWER
LEDs are on.
2. ENSURE SW2 switch (located next to transformer connector J5). Is
set on 120 VAC
3. DISABLE Access Control from 1-2 of IN2 and/or 3-4 of IN1 found on
J3 and place a jumper wire in 3-4 of IN1.