Warning!
The safety features of this product are essential to its compliance with EN 179:2008.
No modification of any kind, other than those described in these instructions, are
permitted. ASSA takes no responsibility for products not mounted as described in
these instructions or if enclosed maintenance and operating instruction not are
followed.
Strike plate
ASSA 179A must be installed together with ASSAs strike plate model 1264 with ordering
numbers 357207, 357208, 357728, 357729, 357730, 357731 and 357732 or with
ASSA’s strike plate model 1487 with ordering numbers 357545,357546, 357547,
357548 and 357549.
Accessories
Emergency exit device ASSA 179A S4 can be installed with outside opening device,
cylinder and/or handle:
Cover plate ASSA S4, ordering no 816944
Cylinder cover plate ASSA S4, ordering no 816940
Cover plate with handle ASSA S4, ordering no 816945
This mounting instruction is intended for installation of
emergency exit device ASSA 179A S4
and
179A-2 S4
with ordering numbers
820137, 820139
and
820140
in combination with ASSA
lock case model
710-35, 721-35, 722-35
and
727-35
with ordering numbers
358663, 357750,
357716 and 357719.
!
MOUNTING INSTRUCTION
ASSA AB 090890
Edition 3
1/7
1.
(3) is suitable for use in high frequency applications;
2.
(6) tested to 100 000 cycles;
3.
(6) for a door mass of up to 200 kg
, door width ≤1320 mm; door height ≤2520 mm;
4.
(B) suitable for use on fire/smoke resisting door assemblies;
5.
(1) is safe for use on escape route doors;
6.
(3) with high corrosion resistance;
7.
(5) with a grade 5 security level 5 000 N;
8.
(2) with a projection of up to 100 mm;
9.
(A) operated with lever handle type A;
10.
(A*) suitable for use on a single door and double door active leaf only with lock case 721-35, 722-35
and 727-35;
*suitable for use on a single door only with lock case 710-35.
Classification according to EN 179:2008
3
6
6
B
1
3
5
2
A
A*
1
2
3
4
5
6
7
8
9
10