background image

Assa 1125 Panikutrymningsbeslag

ASSA 179A S4  Emergency exit device

Cylinder follower

4

Cylinder

3

ASSA AB 090890

Edition 3

3/7

Cut the inside cylinder

follower [   ] according 

to the table below

A

Mount the cylinder / 

cylinders with extended

cylinder follower into the

device with two 13 mm

cylinder screws

A

The B- and C measure is

measured from the center of 

the lock case and towards the 

inner and outer edge of the door 

B

B / C - measure

25 mm
30 mm
35 mm

10 - 13 mm
15 - 18 mm
20 - 23 mm

Cylinder follower 

length

1

Outside

Inside

1

Summary of Contents for 179A S4

Page 1: ...elnummer 816944 Cylinderskylt ASSA S4 artikelnummer 816940 T ckskylt med trycke ASSA S4 artikelnummer 816945 Denna monteringsanvisning avser n dutrymningsbeslag ASSA 179A S4 med artikelnummer 820137 8...

Page 2: ...Utg va 3 2 7 A Montera l shuset exemplet visar l shus 710 35 A Montera samman insidans cylinder styrning med utsidans Om n gon av smalprofilbeh ren saknar cylinder anv nds en mutter bricka mot det akt...

Page 3: ...7 Justera cylinder medbringarens l ngd enligt tabell A Montera cylindern cylindrarna med f rl ngd medbringare i beh ret med tv st 13 mm cylinderskruvar A B och C m ttet m ts fr n l sstolpens centrum t...

Page 4: ...j dern p tryckespinnen med den koniska nden fr n l shuset Assa 1125 Panikutrymningsbeslag ASSA 179A S4 N dutrymningsbeslag Stoppbricka 7 Fyrkantpinne Extra fj der ASSA AB 090890 Utg va 3 4 7 A A 1 2 5...

Page 5: ...ings handtaget i ppnings riktningen L shusets regel fall fallar skall dras in och d rren kunna ppnas Utrymningshand taget skall med l tthet terfj dra till utg ngsl get Montera plomberingstr den Monter...

Page 6: ...nst tv g nger per r Sm rjning med fett p b da sidor av fall och regel skall ske vid installation samt d refter minst tv g nger per r Anv nd sm rjfett med god vidh ftning t ex ASSA L sfett eller liknan...

Page 7: ...Assa 1125 Panikutrymningsbeslag ASSA AB 090890 Utg va 3 7 7 5 RFN FDVH GHSWK 0 1 2SHQLQJ IRU PHUJHQF KDQGOH RQO RQ RQH VLGH 5 5 0 RU VWHHO GRUV RU ZRRG GRUV...

Page 8: ...plate with handle ASSA S4 ordering no 816945 This mounting instruction is intended for installation of emergency exit device ASSA 179A S4 and 179A 2 S4 with ordering numbers 820137 820139 and 820140...

Page 9: ...90890 Edition 3 2 7 A Install the lock case this example shows lock case 710 35 A Mount the inside and outside extension pieces If any of the two narrow profile devices does not have a cylinder a scre...

Page 10: ...according to the table below A Mount the cylinder cylinders with extended cylinder follower into the device with two 13 mm cylinder screws A The B and C measure is measured from the center of the loc...

Page 11: ...cing the lock case Thread the spring onto the follower with the concentric end pointing away from the lock case 1 2 5 6 Right hand device 1 Left hand device 2 1 2 A 1 2 Thread the stop washer onto the...

Page 12: ...return to its starting position Attach enclosed after glowing exit label on the exit handle the arrow on the label shall point in the maneuve ring direction Attach the plastic seal strip A B B Ensure...

Page 13: ...ar maintenance intervals At least twice a year Lubricate both sides of latch and dead bolt at installation and thereafter at least two times per year Use quality grease with high adhesive capacity suc...

Page 14: ...Assa 1125 Panikutrymningsbeslag ASSA AB 090890 Utg va 3 7 7 5 RFN FDVH GHSWK 0 1 2SHQLQJ IRU PHUJHQF KDQGOH RQO RQ RQH VLGH 5 5 0 RU VWHHO GRUV RU ZRRG GRUV...