background image

Assa 1125 Panikutrymningsbeslag

ASSA 179A S4  Emergency exit device

ASSA AB 090890

Edition 3

6/7

Emergency exit device

Regular maintenance intervals: At least once a month

  Check all screws and other fastenings and make sure that they are well constricted,

 

 

also check that the handles operates with ease.

  Open the door by pressing the exit handle downwards. Ensure that the latch moves 

 

 

freely and get a god engagement in the strike plate when the door is closed. The 

 

 

exit handle shall easily return to its starting position after closing.

  If outside handle is connected, also check the re-entry function after opening by the 

 

 

exit handle. Check plastic seal strip and that the after glowing exit label is 

 

 

undamaged and well visible. Replace with a new strip and/or label if necessary.

Lock case

Regular maintenance intervals: At least twice a year

  Lubricate both sides of latch and dead bolt at installation and thereafter at least two 

  times 

per 

year.

  Use quality grease with high adhesive capacity, such as ASSA Lock Grease or similar.

Strike plate

Regular intervals of at least: Six months

  Lubricate the sliding surface between strike plate and latch at installation and 

 

 

thereafter at least two times per year.

  Use quality grease with high adhesive capacity, such as ASSA Lock Grease or similar.

  The gap between door and frame shall be 1-3 mm to insure a proper function. 

 

 

Adjust if necessary.

Lock cylinder

 

Regular intervals of at least: Six months

  Cleaning and lubricating is recommended before summer and winter. Start with use 

 

 

of ASSA Lock Cleaner and then follow up with ASSA Lock Spray for lubrication.

  At high frequency use or hard environment a shorter period of maintenance is 

  recommended. 

 

 

 

Warning!

  Never use oil or graphite lubricants in a lock cylinder

MAINTENANCE AND OPERATING INSTRUCTION

!

Assa 1125 Panikutrymningsbeslag

ASSA AB 090890

Utgåva 3

7/7

5[

/RFNFDVHGHSWK0,1

2SHQLQJIRU(PHUJHQF\KDQGOHRQO\RQRQHVLGH

5[

5[

0[)RUVWHHOGRUV

[)RUZRRGGRUV

Summary of Contents for 179A S4

Page 1: ...elnummer 816944 Cylinderskylt ASSA S4 artikelnummer 816940 T ckskylt med trycke ASSA S4 artikelnummer 816945 Denna monteringsanvisning avser n dutrymningsbeslag ASSA 179A S4 med artikelnummer 820137 8...

Page 2: ...Utg va 3 2 7 A Montera l shuset exemplet visar l shus 710 35 A Montera samman insidans cylinder styrning med utsidans Om n gon av smalprofilbeh ren saknar cylinder anv nds en mutter bricka mot det akt...

Page 3: ...7 Justera cylinder medbringarens l ngd enligt tabell A Montera cylindern cylindrarna med f rl ngd medbringare i beh ret med tv st 13 mm cylinderskruvar A B och C m ttet m ts fr n l sstolpens centrum t...

Page 4: ...j dern p tryckespinnen med den koniska nden fr n l shuset Assa 1125 Panikutrymningsbeslag ASSA 179A S4 N dutrymningsbeslag Stoppbricka 7 Fyrkantpinne Extra fj der ASSA AB 090890 Utg va 3 4 7 A A 1 2 5...

Page 5: ...ings handtaget i ppnings riktningen L shusets regel fall fallar skall dras in och d rren kunna ppnas Utrymningshand taget skall med l tthet terfj dra till utg ngsl get Montera plomberingstr den Monter...

Page 6: ...nst tv g nger per r Sm rjning med fett p b da sidor av fall och regel skall ske vid installation samt d refter minst tv g nger per r Anv nd sm rjfett med god vidh ftning t ex ASSA L sfett eller liknan...

Page 7: ...Assa 1125 Panikutrymningsbeslag ASSA AB 090890 Utg va 3 7 7 5 RFN FDVH GHSWK 0 1 2SHQLQJ IRU PHUJHQF KDQGOH RQO RQ RQH VLGH 5 5 0 RU VWHHO GRUV RU ZRRG GRUV...

Page 8: ...plate with handle ASSA S4 ordering no 816945 This mounting instruction is intended for installation of emergency exit device ASSA 179A S4 and 179A 2 S4 with ordering numbers 820137 820139 and 820140...

Page 9: ...90890 Edition 3 2 7 A Install the lock case this example shows lock case 710 35 A Mount the inside and outside extension pieces If any of the two narrow profile devices does not have a cylinder a scre...

Page 10: ...according to the table below A Mount the cylinder cylinders with extended cylinder follower into the device with two 13 mm cylinder screws A The B and C measure is measured from the center of the loc...

Page 11: ...cing the lock case Thread the spring onto the follower with the concentric end pointing away from the lock case 1 2 5 6 Right hand device 1 Left hand device 2 1 2 A 1 2 Thread the stop washer onto the...

Page 12: ...return to its starting position Attach enclosed after glowing exit label on the exit handle the arrow on the label shall point in the maneuve ring direction Attach the plastic seal strip A B B Ensure...

Page 13: ...ar maintenance intervals At least twice a year Lubricate both sides of latch and dead bolt at installation and thereafter at least two times per year Use quality grease with high adhesive capacity suc...

Page 14: ...Assa 1125 Panikutrymningsbeslag ASSA AB 090890 Utg va 3 7 7 5 RFN FDVH GHSWK 0 1 2SHQLQJ IRU PHUJHQF KDQGOH RQO RQ RQH VLGH 5 5 0 RU VWHHO GRUV RU ZRRG GRUV...