ASR Audio Systems Friedrich Schaefer, D-35745 Herborn, Germany  +49 / 2772 – 42 905

 

High End Integrated Amplifier ASR Emitter I and II  version 2009 on    Page 19

 

 

6.3                

Function of the external ASR battery power supply

 

(optional only for the ASR Emitter Exclusive versions) 

The ASR Battery Power Supply 

is housed in massive separate case. The case contains six 

batteries, each 6Volts/12Ampere-hours and capacitors for buffering summing up to 400,000

F. 

Fuses: 0,5A slow-blow 230V, 1A for 115V (charging transformer), 5A slow (for the batteries)

 

 

In 

Standby

 the circuits inside the ASR Emitter Exclusive are preheated with +/- 10 Volts.  

When charging, the unit is supplied from the charging circuitry. During 

discharging

, the 72VA-

Philbert-Mantelschnitt-transformer is 

separated

 from the AC line via relays in both phases.

 

The battery power supply is switched on the buffering capacitors via Mos Fets. 

All operations are controlled by an optical digital logic circuitry to avoid RF distortions. 

 

 

 

 

 

 

 

 

 

 

 

 

Function and description of the control Leds 

 

turned OFF (

Pos „Off“

): the batteries are charged. The 

yellow

 “

Charge

” Led is shining. 

When 

full

, the 

green 

Leds 

Batt+Full

 and 

Batt-Full

 are shining.

 

 

turned ON (

Pos “Stby”

): the unit is supplied with current out of the charging transformer,  

and the batteries are still charged. The 

red

 “

Standby

” and “

10 V

” Leds are shining.

 

 

turned ON (

Pos 1 or 2

): the main unit is supplied with current out of the external battery 

power supply. The 

yellow

 led “

Amp ON

” and the 

blue

 Led  “

Line Off

” is shining.  

The charging transformer is 

separated

 from the AC power line. After that the 

green  

Led “

Batt On

” and two 

blue

 Leds “

Batt+On

” and “

Bat-On

” are shining.

 

 

during „

Batt ON

“-mode: the voltage is constantly 

monitored

. When the voltage is lower than 

17 Volts the batteries are empty, and the “

Batt Full

” Leds go away. The Battery PSU switches  

into the charging mode- in this mode the main unit is supplied out of the charging transformer.

 

 

Also during charging the batteries the Emitter is working and you can still listen to music.

 

 

when the batteries are 

fully charged 

at 19,5 Volts, the charging transformer will be turned 

Off, and the ASR Emitter Exclusive is 

supplied 

out of the 

batteries

.

 

 

fully charged, the batteries can

 supply

 the ASR Emitter for approximately 

100 hours

.

 

To lengthen the 

lifetime

 of the batteries please turn the Emitter to the „Standby” position for  

one night

 after approximately 

2 days

 of playing in “1 or 2” position. In this case the batteries  

are not so much discharged. Lower quantity of discharging is good for the battery life.

 

One hour of charging is equivalent to about three hours of playing music. 

The ASR Battery Power Supply should not be disconnected from the AC outlet for more than  
3 weeks, other wise the batteries may be damaged by the self discharging of the batteries.

 

Summary of Contents for emitter

Page 1: ...n of the ASR Emitter 8 3 2 Front panel control knobs of the ASR Emitter 8 3 3 Operating the ASR Emitter via ASR remote control 10 3 4 Adjustments of the ASR Emitter 10 4 0 Protection circuits of the A...

Page 2: ...e following items and accessories a Integrated amplifier ASR Emitter main unit with three golden or chromium control knobs b Separate power supply ASR Emitter I one ASR Emitter II two ground switch at...

Page 3: ...S INSIDE THE ASR EMITTER Do not attempt to repair or modify your ASR Emitter All service should be performed by qualified service personnel Do not open the units while it is attached to the AC outlet...

Page 4: ...e ASR Emitter an do the same for the left channel Please make sure that the RCA connectors fits tight 2 1 The balanced input Most ASR Emitters are equipped with a balanced input This input can easily...

Page 5: ...y 49 2772 42 905 High End Integrated Amplifier ASR Emitter I and II version 2009 on Page 5 Better sound quality can be achieved with a separate Phone preamp like the ASR Basis The output of the phono...

Page 6: ...rect input please switch first 30 seconds to Standby before OFF 2 5 Connecting a tape deck to the ASR Emitter The ASR Emitter I is equipped with one the ASR Emitter II with two tape outputs Connect th...

Page 7: ...r with two additional speaker outputs The speaker outputs are named A B and C The additional speaker outputs on the ASR Emitter can be either selected single A or B or together A and B The chosen outp...

Page 8: ...y doubt please switch the ground lift switch to 1 2 8 Connecting the ASR Battery Power Supply The input stages of the ASR Emitter Exclusive versions can be supplied with the optional ASR Battery Power...

Page 9: ...one hour after you put the left control knob to the 1 ON position Tipp about 1 hour before you want to listen to music turn the ASR Emitter on Just turn the ASR Emitter Off if you are not listening t...

Page 10: ...tter is controlled via remote control the position of the left knob may not exactly correspond with the actual operating mode The chosen input is indicated by an Led above the right input selector kno...

Page 11: ...ton decreases the volume left side Mode selects the adjust mode for balance energy saving mode display brightness etc and input level press the Mode button as long until the mode you want to adjust is...

Page 12: ...mode Adjusting the display mode and brightness The display of the ASR Emitter can be adjusted in brightness parts of the display can be illuminated all the time or not and so on The actual setting is...

Page 13: ...mitter can be increased with two switches on the mainboard located in the middle left and right Pos 2 means higher compensation High Compensation increases the stability with difficult loads like high...

Page 14: ...cuit The ASR Emitter is equipped with a sensitive over temperature protection circuit Temperature sensors are located at the large heat sinks of the ASR Emitter If these sensors detect a temperature 5...

Page 15: ...ow EGY and 2 green Driver Leds are shining In Full power mode three blue Leds Power are shining When the corresponding Leds are shining in the power supplies but not in the main unit please check the...

Page 16: ...s and with the original ASR packing accessories Your authorized ASR Audio Systems dealer will take care of your unit and will repair it properly 6 0 Facts about the ASR Emitter 6 1 Function of the ASR...

Page 17: ...input relay are shining With battery PSU the input stage is supplied with low voltage for preheating In Position 1 2 and the further positions the amp switches ON the external PSU This is shown with...

Page 18: ...in front of the main PCB board in the PSU The two yellow an blue Leds in the middle show that the Emitter has given the signal the Leds left and right that the voltages are present In Off and Standby...

Page 19: ...d Standby and 10 V Leds are shining turned ON Pos 1 or 2 the main unit is supplied with current out of the external battery power supply The yellow led Amp ON and the blue Led Line Off is shining The...

Page 20: ...eparate transformers and rectifiers for positive and negative voltages two transformers each in separated cases per channel for the ASR Emitter II A built in 72 VA transformer supplies the input stage...

Page 21: ...s ASR Emitter I 42 0 x 41 0 x 18 0 cm 22 kg power supply 46 0 x 32 0 x 16 0 cm 32 0 kg 16 5 x 16 1 x 7 1 inches 48 lbs power supply 16 9 x 15 6 x 5 9 inches 71 lbs ASR Emitter II 57 0 x 44 0 x 23 0 cm...

Reviews: