Aspirante thermostatic power shower
8
ADJUSTING THE MAXIMUM
TEMPErATUrE STOP
As a safety feature the shower has a built-in
maximum temperature stop to prevent you
accidentally exceeding your highest desired
temperature. This is set in the factory to provide
a maximum temperature based on the hot
and cold water supplies being 65°C and 15°C
respectively.
Procedure:
Pull off the temperature control
(fig.)
.
Carefully pull off the maximum temperature
stop mechanism.
To increase the temperature stop setting,
reposition the mechanism anti-clockwise within
the arc of the grooves
(fig.)
.
To decrease the temperature stop setting,
reposition the mechanism clockwise within the
arc of the grooves
(fig.)
.
Replace the temperature control by push fitting
onto the adaptor shaft, noting that it will only fit
one way.
Important:
only adjust the maximum
temperature stop when the hot water is at its
usual storage temperature.
Fig.
Increase stop position
Maximum
temperature
stop
Decrease stop position
Fig.