Aspirante thermostatic power shower

Terminal block

Fig.8

Important:

 The earth continuity to the 

cover of the shower must be checked and 
approved, by a qualified electrician when 
the shower is installed, and at least every 
2 years thereafter.

ELECTrICAL CONNECTIONS

The supply cable must conform to relevant 
tables in current IEE regulations. In most cases 
1 mm² twin and earth will be adequate.
The electrical rating of the shower is on the 
rating label within the unit.
Cable entry points are shown in 

fig.

. Conduit 

entry can only be from the rear.
Route the cable into the shower, taking care to 
avoid the area of the wall fixings and connect to 
the terminal block

 (fig.8) 

as follows:

Live cable to terminal marked 

L

neutral cable to terminal marked 

n

Earth cable to terminal marked 

Important:

 

fully tighten the terminal block 

screws and check that no cable insulation is 
trapped under the screws. 

note:

 The supply cable earth conductor must 

be sleeved.
The earth continuity conductor of the electrical 
installation must be effectively connected 
electrically to all exposed metal parts of other 
appliances and services in the room in which the 
shower is to be installed, to conform to current 
IEE regulations.

note:

 Fuses do not guarantee user protection 

against electric shock. In the interest of electrical 
safety, all mains electric and pumped showers 
should be fitted with a 30mA residual current 
device (RCD). This may be part of the consumer 
unit or a separate unit.

Do NoT switch on the electricity supply until 
the water has been turned on to the unit and 
connections have been tested for leaks.

WarnInG!

 thIs appLIancE must BE 

EarthEd

Summary of Contents for ASP2000THM

Page 1: ...Installers please note these instructions are to be left with the user 2180298L October 2009 Installation and operating instructions Aspirante power shower...

Page 2: ...sioning and setup procedure 13 Replacing the cover 15 Temperature control spindle setting 16 Operating the shower 17 Adjusting the maximum temperature stop 18 Cleaning 19 Instructions for installers a...

Page 3: ...e then 1 9 1 The anticipated flow rate may not be achieved 1 9 2 Air may be drawn into the hot supply from the vent pipe causing spluttering and temperature fluctuations at the showerhead 1 10 Fullway...

Page 4: ...ed 15 minutes on 45 minutes off duty cycle SAFETY WARNINGS 1 Do not insert fingers into the push in inlet fittings Doing so could cause injury 2 Under no circumstances must this product be connected t...

Page 5: ...fails 3 Shut down to seepage is achieved even if the hot supply is only 12 C above the blend temperature 4 The blended water temperature is maintained within 1 C when the pressure between inlet and o...

Page 6: ...ection of pipework from the cylinder Alternatively the connection can be taken from the hot supply pipe to other outlets as long as it is the first draw off below the ventilation pipe tee Fig 3 illust...

Page 7: ...d Hot feed connection above vent tee Cold supply from cylinder feed Hot feed connection from horizontal vent pipe Strained hose No isolating valves Soap dish retaining ring not used Mains supply Suppl...

Page 8: ...te Allow enough room between the ceiling and the shower unit to access the top cover screw Position the shower and showerhead on the wall so that all controls can be comfortably reached while using th...

Page 9: ...will reveal the maximum temperature stop fig 7 This should be left in position Note If adjustment of the maximum temperature stop is required refer to section Adjusting the maximum temperature stop R...

Page 10: ...ff point and the shower A dedicated cold water supply must be taken directly from the cold water cistern to the shower This draw off must be positioned 25 mm below the cold feed connection to the hot...

Page 11: ...of a tool Note The pipe inlets contain filters These should be periodically removed and cleaned in order to maintain the performance of the shower See section cleaning on how to access the filters Tw...

Page 12: ...pleted before fixing the shower to the wall Offer the backplate unit up to the completed pipework and manoeuvre so that the end of the pipes enter fully into the inlet fittings Mark positions for wall...

Page 13: ...that debris does not enter the pipes when drilling the wall Offer the back plate unit up to the completed pipework and manoeuvre so that the end of the pipes enter fully into the inlet fittings Check...

Page 14: ...eutral cable to terminal marked N Earth cable to terminal marked E Important Fully tighten the terminal block screws and check that no cable insulation is trapped under the screws Note The supply cabl...

Page 15: ...electricity is switched on temporarily Fit the temperature control onto the adaptor fig 19 This is a push fit and will only fit one way On the PCB make sure the commissioning link is positioned on th...

Page 16: ...as been used then seal around pipes with mastic to prevent the possibility of water entering the wall cavity Do not use plaster as this could cause difficulty if maintenance is required at a later dat...

Page 17: ...m temperature stop is still in position Note If adjustment of the maximum temperature stop is required refer to section Adjusting the maximum temperature stop Replace the temperature control knob by p...

Page 18: ...ine on the adaptor with both the black spindle mark and the housing groove the double line will be at the 8 o clock position The temperature control location open end must relate to 5 on the temperatu...

Page 19: ...shower should also be switched off at the electricity isolating switch As a safety feature the temperature control has a built in stop to prevent you accidentally exceeding your highest desired temper...

Page 20: ...fig 32 Carefully pull off the maximum temperature stop mechanism To increase the temperature stop setting reposition the mechanism anti clockwise within the arc of the grooves fig 33 To decrease the...

Page 21: ...erformance of the shower The hardness of the water will determine the frequency of cleaning For example if the shower is used every day in a very hard water area it may be necessary to clean the showe...

Page 22: ...filter cover fig 34 depending upon whether top rear entry or bottom entry is used Pull off the filter cover Carefully hook out the filters together with O rings Thoroughly clean and replace ensuring t...

Page 23: ...77 6 Temperature valve thermostatic 83305270 7 Solenoid assembly 22012190 8 Filter pair 83305330 Pipe inlet elbow c w filters check valves 83305320 Temperature control c w override button 83305260 Max...

Page 24: ...If it fails again consult a competent electrician 3 1 2 Power cut Check other appliances and if necessary contact local Electricity Supply Company 3 2 1 Consult a competent electrician or contact Cust...

Page 25: ...of hot and cold water into system 6 Water dripping from showerhead when turned off 4 1 Water supplies cut off 4 2 Shower blocked or air in the system 4 3 Showerhead blocked 4 4 Blocked filters 5 1 Dir...

Page 26: ...Aspirante thermostatic power shower 24...

Page 27: ...Aspirante thermostatic power shower 25...

Page 28: ...usly and expects customers to treat all staff members with respect Should any employee feel threatened or receive abuse either verbally or physically Triton reserves the right to withhold service and...

Page 29: ...Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more...

Reviews: