30
E N G L I S H
ASPIRCOMFORT PRO X 380V
High
vibrations
Vibrating panels
Check the integrity of the unit panels
and profiles
Check the correct closing of the unit
cover and the panel that covers the
electronic board
Make sure there are no walls that can
transmit vibrations to the wall / floor /
false ceilings
Imbalanced fan blades
Check the integrity of the blades
Clean the fans
Make sure the small metal blade
balancing clips are still on the fans
Condensation leak
Clogged condensation discharge
Clean the condensate discharge.
The condensation does not flow from
the discharge duct to the collection
tray
Make sure that the unit is perfectly
level
Check that the condensation discharge
connections are not clogged
The appliance does not
switch on
No power supply
Check whether there is voltage in the
mains (by switching on a light bulb in
the house, for example).
Check that the exclusive
thermomagnetic switch protecting
the appliance has not tripped (if so,
reset it). If the problem recurs, contact
the Service Department immediately
and do not attempt to operate the
appliance.
The appliance does not
cool/heat sufficiently
Set temperature too high or too low
Check and correct the temperature
setting if necessary.
The air filter is clogged
Check the air filter and clean it if
necessary.
Check that there are no obstructions to
the flow of air inside or outside.
Remove anything that might obstruct
airflow.