9
E N G L I S H
ASPIRCOMFORT PRO X 380V
2. INSTALLATION
2.1 INSTALLATION CONDITIONS
The unit must be installed based on national and local regulations governing the use of electrical devices
and based on the following indications:
• install the unit inside residential buildings with room temperature between 0°C and 45°C;
• avoid areas near sources of heat, steam, inflammable and/or explosive gases and particularly dusty areas;
• install the unit in a place that is not subject to frost (the condensation water must be discharged not frozen, at
a certain slope, using a trap);
• do not install the unit in zones with a high relative humidity rate (such as bathroom or toilet) to avoid
condensation on the external surface;
• choose a place of installation where there is enough room around the unit for the connections of the air ducts
and to perform maintenance activities;
• the consistency of the ceiling/wall/floor where the unit will be installed must be suitable for the weight of the
unit and not cause vibrations.
The installation position of the unit, in order to obtain the best operating efficiency and to avoid faults or hazardous
conditions, must have the following requirements:
- Respect the spaces indicated in the figure.
- The wall on which the unit is to be fixed must be sturdy and suitable to support its weight.
- It must be possible to leave space around the unit for maintenance.
- There must be no obstacles to the free circulation of air in the upper intake area (curtains, plants, furniture) or
in the front air outlet area; this could cause turbulence that would inhibit the correct operation of the appliance.
- The unit can be placed on the floor or suspended.
- The appliance is rated IPX0, so it is not suitable for outdoor installation.
- Check that there are no structures or installations (beams, pillars, water pipes, electric cables, etc.) at the
points where you intend to drill the holes that would prevent the necessary holes from being drilled. Check that
there are no obstacles to the free circulation of air through the holes you are going to make (plants and their
foliage, slats, shutters, grills or grates that are too thick, etc.).
- The appliance must not be in a position where the air flow is aimed directly at people nearby.
- The appliance is not directly above an electrical appliance (television, radio, refrigerator, etc.), or above a heat
source.
The room chosen for installation must have:
- Outdoor air duct connections;
- 230V single-phase electrical connection;