Checklist / Lista de verificación

 ITEM  DESCRIPTION

  1

 

Does pump voltage conform with evaporator 

 

 

supply voltage?

  2

 

Is actual power input sufficient to drive pump?

  3

 

Is pump permanently energized regardless of    

 

 

evaporator operation?

  4

 

Is fuse installed?

  5

 

Is overflow switch (gray and purple wires) correctly  

 

 

wired into communication wire to ensure unit    

 

 

will not operate in case of pump failure or blockage?

  6

 

Is piping & wiring in accordance with  

 

 

 

manufacturer’s instructions?

  7

 

Is pump correctly sized to handle  condensate output  

 

 

of evaporator?

  8

 

Is maximum head within pump limits?

 ITEM  DESCRIPTION

  9

 

Is discharge hose sized at 1/4” i.d. as per   

 

               manufacturer’s instructions?

  10

 

Is discharge hose watertight? 

  11

 

Is reservoir level?

  12

 

Is float in position?

  13

 

Is magnet facing upwards on float?

  14

 

Is filter present in reservoir?

  15

 

Has provision been made to prevent siphoning?

  16

 

Is drain discharge hose clear of restrictions?

  17

 

Is intake hose watertight?

  18

 

Is breather tube installed and free of restrictions?

  19

 

Is pump correctly connected to ensure water flow  

 

 

towards discharge hose?

  20

 

Is pump wrapped with damping material to  

 

 

 

eliminate vibration

PREVENTION OF SIPHONING

Ensure that end of discharge hose is higher than water level in evaporator drain pan.
If condensate discharge point must be lower than drainpan then 1/4” discharge hose from pump must empty 

into a larger diameter drain pipe at a higher level than drainpan. 
THIS JOINT MUST INCORPORATE AN AIR BREAK TO PREVENT SIPHONING.
FOR FULL DETAILS ON SIPHONING, CONSULT ASPEN PUBLICATION: GUIDELINES FOR CORRECT INSTALLATION 

OF DISCHARGE HOSING, ON LAST PAGES OF THIS MANUAL.

               

PREVENCIӔN DEL EFECTO SIFON

Cerciórese de que el extremo de la manguera de descarga esté en un nivel más alto que el nivel del agua en la 

bandeja de desagüe del evaporador.
Si el punto de descarga de agua de condensación debe estar más abajo que la bandeja de desagüe, la 

manguera de descarga de 1/4” de d.i. proveniente de la bomba debe vaciarse en una tubería de desagüe que 

tenga un diámetro mayor y esté en un nivel más alto que la bandeja. 
ÉSTE UNIÓN ENTRE EL TUBO y LA MANGUERA NO DEBE SER HERMÉTICA PERMITIENDO HAyA UN ESPACIO 

ENTRE AMBAS SUPERFICIES DE CONTACTO PARA EVITAR EL EFECTO SIFON.
SI DESEA MAyORES DETALLES SOBRE EL SINFONAJE, CONSULTE LA PUBLICACIÓN DE ASPEN: PAUTAS PARA

LA CORRECTA INSTALACIÓN DE LA MANGUERA DE DESCARGA, EN ULTIMO PAGINAS DE ESTA MANUAL.

ES

ENG

ENG

falSe ceIlINg / 

TecHo falSo

eND of 

DIScHarge Tube /

exTremo Del 

maNguera De 

DeScarga

aIr break /

eSPacIo Del 

aIre

ToP of breaTHer 

Tube /

ParTe SuPerIor

Del Tubo 

reSPIraDor

WaTer leVel IN DraIN TraY /

NIVel De agua eN la baNDeja De 

DeSagÜe Del eVaPoraDor

6

Summary of Contents for Maxi Orange

Page 1: ...s not conform in terms of color type and specifications to the original product if no longer available This warranty does not cover replacement labor or any cost claim or incident to any defect nor do...

Page 2: ...LIMENTACI N EL CTRICA Mini Orange 115V CA 0 18A 15w 60HZ 230V CA 0 11A 16w 60HZ 24V CA 0 7A 16w 60HZ Maxi Orange 115V CA 0 28A 21w 60HZ 230V CA 0 15A 21w 60HZ Cables de alarma de 3A sin voltios contac...

Page 3: ...entrada de hule color naranja 5 Manguera de conector de pl stico de 5 de longtitud y 1 4 de d i 6 Conjunto de cable de alimentaci n naranja de 6 pies 7 Tubo respirador de pl stico con 6 de longtitud...

Page 4: ...RRANTY NO HAGA FUNCIONAR LA BOMBA EN SECO OCURRIR N DA OS GRAVES QUE DEJAR N NULA LA GARANT A ES ENG We recommeND uSINg THIS PumP for No greaTer THaN 26ft HeaD No recomeNDamoS el fuNcIoNamIeNTo Sobre...

Page 5: ...INI AND MAxI ORANGE PUMPS ARE DESIGNED TO OPERATE AT EITHER 115 OR 230 VOLTS AC 60HZ wITH A TOLERANCE OF OR 10 IN BUILDINGS wIRED FOR 208 VOLTS THE 230 VOLT PUMPS SHOULD OPERATE NORMALLy PROVIDED THIS...

Page 6: ...vaporator drain pan If condensate discharge point must be lower than drainpan then 1 4 discharge hose from pump must empty into a larger diameter drain pipe at a higher level than drainpan THIS JOINT...

Page 7: ...el im n de metal en el flotador est apuntando hacia arriba Aseg rarse siempre de que el dep sito se asiente plano y horizontal Las bombas est n ideal para la mayor a de los ambientes de trabajo y vivi...

Page 8: ...ing on surface of drainpan Installation reservoir Instalaci n dep sito Select correct reservoir type A inline or B panmount 1 Insert filter into reservoir selected DO NOT OPERATE THIS PUMP wITHOUT FIL...

Page 9: ...asegurado plano y horizontal debajo de la bandeja de desag e utilizando las tiras de velcro autoadhesivas DEP SITO A En linea Para conectar directamente en la montaje de plastico al final de la mangue...

Page 10: ...RADOR DONDE LO PERMITA EL ESPACIO 2 INSIDE LINESET COVER DENTRO DE LA CUBIERTA DE TUBER A DE COBRE 3 ABOVE CEILING POR ENCIMA EL TECHO FALSO ENG ES Install pump unit in evaporator casing above ceiling...

Page 11: ...a de la bomba y asegurela con un sujetador pl stico NO LA USE UNA MANGUERA DE DESCARGA MAS GRANDE DE de d i Direccione la manguera de descarga a un drenaje appropriado MINI ORANGE MAxIMUM 26FT MINI OR...

Page 12: ...gun el diagrama pertinente y adhiera la etiqueta de advertencia en la parte delantera de la cubierta del terminales NO USE LINEAS INDEPENDIENTES DE 115 o 230 VOLTIOS PARA ALIMENTAR LA BOMBA yA QUE EST...

Page 13: ...ommunication wire L2 G 3 3 N N L 3 G neutral neutro terminal block in condenser bloque de terminales en condensador 1 amp fuse 1 amp fusible wire nut or crimp tuerca o engarce wire nut or crimp tuerca...

Page 14: ...HT TO ELIMINATE AIR IN HOSES REFER TO PREVENTION OF SIPHONING SECTION ON PAGE 6 AND TO DETAILED GUIDELINES FOR CORRECT INSTALLATION OF DISCHARGE HOSING ON LAST PAGES OF THIS MANUAL IF NECESSARy REFER...

Page 15: ...re there any restrictions in discharge hose or breather tube f Check that reservoir filter and discharge hose are free of sludge and debris Fault Pump doesn t operate at all 1 a Is power reaching the...

Page 16: ...NSTALLATION 6 INSTALL PIPE AND WIRE STRICTLY IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS DO NOT USE DISCHARGE HOSE LARGER THAN 1 4 i d 7 DO NOT OPERATE PUMP WITHOUT FILTER 8 DO NOT RUN PUMP DRY SERI...

Page 17: ...IS VITAL THAT THE INTAKE HOSE IS KEPT FULL OF WATER AT ALL TIMES SO THAT NO AIR IS PRESENT FOR THE PUMP TO DRAW IN WHEN IT STARTS OPERATING AS LONG AS THE INTAKE HOSE REMAINS FULL OF WATER EVERY TIME...

Page 18: ...hose are completely empty at which point the siphoning stops 4 As the evaporator produces more condensate the drain pan again fills up with water which flows into the reservoir Since the intake hose...

Page 19: ...gh the pump and out of the discharge hose 3 Water level in the reservoir has now receded enough to lower the float which deactivates the pump however since an air gap is included in the discharge hose...

Page 20: ...ENZAR LA INSTALACI N 6 INSTALE PONGA TUBER AS Y CABLES ESTRICTAMENTE EN CONFORMIDAD CON LAS INSTRUCCIONES DEL FABRICANTE NO LA USE UNA MANGUERA DE DESCARGA MAS GRANDE QUE de d i 7 NO HAGA FUNCIONAR LA...

Page 21: ...O DE ESA MANERA NO HABRA AIRE QUE SEA SUCCIONADO POR LA BOMBA CUANDO EST EMPIECE A OPERAR TANTO COMO LA MANGUERA DE ENTRADA PERMANEZCA LLENA DE AGUA CADA VEZ QUE LA BOMBA ARRANQUE SERA INMEDIATAMENTE...

Page 22: ...aporador produce m s conden sados la bandeja de desag e se llena de nuevo con agua la cual fluye al dep sito Al haber aire en la manguera de entrada el ciclo se repite por s solo LA PROBLEMA ES QUE CA...

Page 23: ...bomba LA MANGUERA DE ENTRADA YA ESTA LLENA CON AGUA de all que no sea succionado aire y la bomba es inmediatamente enfriada y lubricada NO SERA ESCUCHADO EL GOLPETEO LA BOMBA AHORA EST OPERANDO ENTERA...

Page 24: ...duct Lineset covers aspen Mini condensate pumps novent Locking refrigerant caps big foot AC rooftop mounting system airtec AC equipment mounting slimduct Condensate drain hose airtec products corp 124...

Reviews: