4 MAN-PH-E-16
© by ASM GmbH
www.asm-sensor.com / USA: www.asmsensors.com
POSIHALL
®
Safety instructions
Integrity of housing,
connector, cable
Mounting
elements
Visual check of
shaft sealing
PH36
X
X
X
PH58
X
X
X
PH68 / PH68R
X
X
X
Measures
Damaged parts: Put
sensor out of service and
replace damaged parts
resp. send sensor to ASM
for repair
Loose mounting parts:
Screw tight mounting parts
with recommended torque,
if applicable use bolt
adhesive
Damaged shaft sealing:
Put sensor out of ser-
vice and send it to ASM
for repair
Intended use
Unintended use
Maintenance and
service
•
In order to avoid risk of injury and improper handling the customer
is not allowed to repair the sensor. No warranty or liability will be
granted for opened sensors.
•
Damaged sensors must be shut down immediately and sent to the
factory for repair.
Proper maintenance comprises the visual examination of parts (e.g. inte-
grity of housing, connectors and cables). Maintenance intervals depend on
the specific application and should be defined by the user in dependence
of operating conditions.
The following maintenance steps are recommended:
Maintenance-
interval
The intended use is when the sensor is used in the properly rated ambient
atmospheric and technical conditions for which the sensor is designated.
The unintended use is when the sensor is used outside its specified technical
and ambient atmospheric conditions or when improperly mounted.
Deinstallation
Disconnect electrical connections. Loosen fixing screws.
Disposal
Disposal according to applicable government regulations.
Do not open the sensor
!
The maximum operating voltage may not exceed the limits specified
in the respective data sheet!
•
Danger of injury! Danger of damage to or destruction of the sensor!
Avoid shock and vibration to the sensor!
•
Danger of damage to or destruction of the sensor!
Safety
instructions