10 MAN-PH-E-16
© by ASM GmbH
www.asm-sensor.com / USA: www.asmsensors.com
POSIHALL
®
Electrical installation
Torque for fixing screws
•
The specified torques and mounting methods are general recommenda
-
tions.
•
The specified torques can differ according to application and operating
conditions.
•
The user is responsible for the appropriate torque, since ASM does not
know the operational conditions of the application.
Output
Value range
50% value of output signal
U2
0.5 ... 10 V
5.25 V
U6
0.5 ... 4.5 V
2.5 V
U8
0.5 ... 4.5 V
2.5 V
I1
4 ... 20 mA
12 mA
Mounting
Torque
Mounting methos
Material
Torque
[Nm]
M2.5 screws for mounting brackets
Aluminium
0.8
M3 screws for mounting flange
Aluminium
1.0
Screws M4
Aluminium
1.8
Observe different color code for pre-assembled accessory cables - refer
to accessories pages.
The protection class of sensors with connector output is valid only if the
electrical plug is connected!
Do not twist the M12 connector insert.
Cable outputs must be installed in such a way that no moisture can get
into the cable. Crossing the dew point must be avoided.
Do not strain the connection cable.
A separate cord grip is recommended.
For wiring of connector or cable outlet as well as supply voltage and cur-
rent consumption see from page 13.
Cable screen has to be connected to protective earth.
Electrical installation
Supply voltage,
current
consumption
NOTICE