E (=>mm)
D (=>mm)
C (mm)
B (=>mm)
A (mm)
50
40
490-492
600
350-352
38 cm
50
40
490-492
600
560-562
64/72 cm
50
40
490-492
600
750-752
80 cm
50
40
490-492
600
770-772
80 cm - 5 zones
50
40
490-492
600
860-862
90 cm
50
40
385-387
500
1070-1072
111 cm
Air vents in the lower kitchen cabinet
•
Normal operation of the induction cooking hob electronic components requires sufficient air
circulation.
Lower cabinet with a drawer
•
There must be an opening with a height of
no less than 140 mm along the entire width
of the cabinet in the cabinet rear wall. In
addition, there should be an opening of at
least 6 mm in the front side, along the
entire width of the cupboard.
•
A horizontal partition panel should be
installed underneath the cooking hob
along its entire length. There should be at
least 20 mm of clearance between the
lower end of the appliance and the
partition panel. Adequate ventilation
should be allowed from the rear side.
•
The hob is fitted with a fan located in its lower part. If there is a drawer below the kitchen cabinet,
do not use it to store small objects or paper as these could, if sucked into the fan, damage the
fan and the cooling system. Moreover, do not use the drawer to store aluminium foil or flammable
substances or liquids (such as sprays). Keep such substances away from the cooking hob.
Danger of explosion! There should be at least 20 mm of clearance between the contents of the
drawer and the fan inlet vents.
9
Installation