1 phase, 1 neutral conductor (220–240 V~, 50/60 Hz)
L
= black/brown
N
= blue
= yellow-green
For appliance types: BI1CA…, BI6CA…, BI6CB…, BI7CA…, BI8CA…, BI8CB…, BI9CE…
Voltage between line and neutral conductor must be 220–240 V~. Voltage between lines must be
380–415 V~.
Power cord core cross sectional area should be at least as listed in Table for the following current
limiter settings which should be adjusted to your circuit breakers:
Number and cross section
of Power cord wires
Power cord
Type
Connection type
Current
limiter
settings
4x1,5mm²
H05VV-F
2 phases, 1 neutral conductor
2x16A
4x1,5mm²
H05VV-F
2 phases, 1 neutral conductor
2x13A
4x1,5mm²
H05VV-F
2 phases, 1 neutral conductor
2x10A
4x1,5mm²
H05VV-F
2 phases, 1 neutral conductor
2x06A
5x1,5mm²
H05VV-F
2 phases, 2 neutral conductors (only
for NL)
2x16A
3x4,0mm²
H05VV-F
1 phase, 1 neutral conductor
1x32A
3x4,0mm²
H05VV-F
1 phase, 1 neutral conductor
1x25A
3x4,0mm²
H05VV-F
1 phase, 1 neutral conductor
1x20A
3x4,0mm²
H05VV-F
1 phase, 1 neutral conductor
1x16A
3x4,0mm²
H05VV-F
1 phase, 1 neutral conductor
1x13A
3x4,0mm²
H05VV-F
1 phase, 1 neutral conductor
1x10A
3x4,0mm²
H05VV-F
1 phase, 1 neutral conductor
1x06A
The following connections are possible.
1 phase, 1 neutral conductor (220–240 V~, 50-60 Hz)
To reach the rated maximum power a fuse of 32A is needed.
Install a jumper between terminals 1 and 2, between terminals 2 and 3
and between terminals 4 and 5.
15
Connecting