Service manual DW Outdoor
20
Service menu
Menu step/Turn/Push
LCD
Comments/instructions
START
Diagnostics
PROG
d:01
Mixer valve and inlet valve on (1 second delay between mixer
valve, if available, and inlet valve)
d:02
Inlet valve and mixer valve, if available, off for 1 second then inlet
valve on
d:03
Salt valve on (if available)
d:04
Combi dispenser on
d:05
Circulation pump on and the spray arm diverter (if available) shall
alternate between positions 1 and 3 every 30 seconds
d:06
Circulation pump and heater on - max. 75°C (167°F)
d:07
Fan and Wax motor and Turbo Drying Express and Heating
Water Circuit on
d:08
Drain pump on
d:00
No components on
START
Water intake
PROG
P:0
Normal water intake volume, default setting
P:5
Water intake volume increases by +5%
P:10
Water intake volume increases by +10%
P:15
Water intake volume increases by +15%
L:0
Time, fl ow meter switched off, intake time:
pulse value x 0.068 [s]
L:5
Time-controlled water intake increases by +5%
L:10
Time-controlled water intake increases by +10%
L:15
Time-controlled water intake increases by +15%
START
T8
T1
LCD1
T3
T4
T5
T6
T7
T2
D1, I5,
D2, D3
Variant 1
Variant 2
Variant 3
Variant 4
Opening the service menu
PROG + START
Open the door, put the machine in standby mode by pressing the main power switch (T8).
Activate the machine again by pressing the button (T8), press and hold the program selector
(T1) and (T2) for 5 sec. LCD shows:
. When the service menu is opened the most recent
error message is shown, F:XX. All error messages are erased by a total reset. It is only possible
to leave the service menu by pressing the button (T2). It is not possible to leave the service
menu by using the main power switch (T8).
START
Press the button (T2) to navigate the menu system step by step.
PROG
Press the button (T1) to scroll between settings. Press (T2) to save the setting and continue to
the next menu step.
START
Press (T2) at the last step of the menu to close the service menu and save the most recent
settings.