Service manual DW Outdoor
15
WIRES IN ALL MACHINES
INTERNAL CONNECTION
WIRES IN SOME MACHINES
COMBI DISPENSER
CIRCULATION PUMP
WATER DIVERTER VALVE
DRAIN PUMP
DOOR
DOOR SWITCH
FILTER
FLOW METER
FAN DOOR
FAN BOTTOM
FLOAT SWITCH
HEATING ELEMENT
HEATING ELEMENT PTC
HALOGEN LAMP
HUMIDITY SENSOR
ILLUM. SWITCH
INLET VALVE
I2C
MAIN SWITCH
MIX VALVE
PRESSURE SENSOR
RINSE AID SENSOR
STATUS LIGHT
SALT SENSOR
SALT VALVE
THERMISTOR
TURBIDITY SENSOR
UART
VAX ACTUATOR
HOT WATER CIRCUIT
KD/CD:
CP:
DIV:
AP/DP:
DR:
LB/DS:
F:
FM:
FL/FN 1:
FAN/FN 2:
FS:
EL/HE:
HE (PTC):
BE/HL:
HS:
IS:
IV:
I2C:
TB/MS:
MV:
TS/PS:
VMG/RAS:
SL:
SG/SS:
SV:
NTC/TH:
GS/TS:
UART:
VAX:
HWC:
RESISTANCE
1 MOHM
12 OHM
32 OHM
25 OHM
60 KOHM
0,28 KOHM
1,32 KOHM
32 OHM
110 OHM
56 OHM
25 OHM
150 OHM
85 OHM
2.6 KOHM
8,5 KOHM
0.95 KOHM
0.5 KOHM
3,9 KOHM
2 KOHM
0,65 KOHM
0,65 KOHM
3 KOHM
2,3 KOHM
<10 KOHM
1.1 KOHM
0.18 KOHM
0,85 KOHM
0,22 KOHM
0,90 KOHM
RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F)
VALUES WITH +/-10% ARE REGARDED AS NORMAL
COMPONENT
RADIO INTERFERENCE SUPPRESSION FILTER
HEATING ELEMENT 1200W 120V
HEATING ELEMENT 1600W 230V
HEATING ELEMENT 2040W 230V
THERMISTOR
COMBINED DISPENSER 120V
COMBINED DISPENSER 230V
CIRCULATION PUMP 120V 60HZ
CIRCULATION PUMP 230V 50HZ
CIRCULATION PUMP 220V 60HZ
DRAIN PUMP 120V 60HZ
DRAIN PUMP 230V 50HZ
DRAIN PUMP 230V 60HZ
SPRAY ARM DIVIDER 120V 60HZ
SPRAY ARM DIVIDER 230V 50/60HZ
INLET VALVE SINGLE INCL. 120V
INLET VALVE SAFETY INCL. 120V
INLET VALVE SINGLE INCL. 230V
INLET VALVE SAFETY INCL. 230V
SALT VALVE 120V
MIX VALVE 120V
SALT VALVE 230V
MIX VALVE 230V
HALOGEN LAMP 5W 12V
WAX MOTOR
FAN MOTOR 120V
FAN MOTOR 230V
FAN MOTOR 2 120V
FAN MOTOR 2 230V