46
Maintenance - 2
BAKIM PLANI:
Control Parameter
Control Point
#
Control
Period
Spark Arrestor
Metal Prefilter
Dust Tray
Service Cover Seals
Main Filter (1), (2)
Dirty Filter Signal
Clean Air Side (1), (2)
Main Filter (1), (2)
- Remove Main Filter element and control
metal dust tray! Empty Dust tray if neces-
sary!
- Control Fan and Filter cover seals! If wear
or adhesion issues occur, replace seals!
- Change Main Filter if signal activates
- If wear or small holes present, change
faulty hoses!
- Control Clean air side through Filter
Service Cover!
- If Dust residue is present, Change Main
Filter!
- If Fire signs present, extinguish
fire according to FIRE SAFETY
INSTRUCTIONS!
- Remove Main Filter element and sparks
arrestor metal mesh filter respectively and
control metal prefilter!
- If necessary clean metal prefilter!
- If necessary Wash and fully dry metal
prefilter.
- Change main Filter!
- Control Clean air side through Filter
Service Cover!
- If Dust residue is present, Change Main
Filter!
560 hours
7
560 hours
8
8 hours
1
40 hours
2
40 hours
3
560 hours
6
560 hours
5
40 hours
4
Extraction Arm Hoses
US
E
R
G
UI
D
E