43
Operation - 3
- WARNING! All Installation, maintenance and repair
work must be implemented by trained and authorized
electrician and maintenance technicians!
- If supplied electrical plug is not compatible with existing
plant infrastructure;
Authorized electrician shall change supplied plug with
a compatible plug (3 phase + 1 N 1 Earth) 5 pin
min.16 A.
Correct Fan Direction is labelled inside
Filter Service Cover zone!
ELECTRICAL CONNECTION AND CONTROL OF FAN ROTATION
DIRECTION:
Filter unit is delivered ready-to-use industrial plug 5x16A 3P N PE (3 phase+1 Neutral
+1 Earth).
Follow below instruction at first-time commissioning and every time filter unit is
connected to a different plug!
1) Connect plug to electrical connection
2) Turn on main switch for 3 seconds and turn off main switch!