47
Maintenance - 3
PROBLEM (1) : Insufficient Air Suction
PROBLEM (2) : Dust Residue inside Clean Air Side
PROBLEM (3) : Dusty Air is blowing at the air outlet
Cause
Cause
Cause
Extraction Arm Elbow
Angles are too small
Main Filter is clogged
Remedy
Remedy
Remedy
- Control the direction of fan rotation and
interchange two phase lead at the plug if
necessary!
- Change main filter! Contact ASKAYNAK
service for spare filter element!
- Change main filter! Contact ASKAYNAK
service for spare filter element!
- Airflow could decrease according to
extraction arm elbow angles and condition
of the main filter. Change angles if possible!
- Change main filter! Contact ASKAYNAK
service for spare filter element!
False Fan Rotation Direction
Faulty Filter element or Seal
Faulty Filter element
TROUBLESHOOTING:
US
E
R
G
UI
D
E