background image

30" (76.2 CM) RANGE HOOD LINER

Installation Instructions and Use & Care Guide

CAISSE DE HOTTE POUR CUISINIÈRE 

DE 30" (76,2 CM)

Instructions d’installation et Guide d’utilisation et d’entretien

Table of Contents/Table des matières............................................................................. 2

IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
                       FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
                        POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.

LI30ZC/W10487239D

Summary of Contents for UXL5430BSS1

Page 1: ...ISINIÈRE DE 30 76 2 CM Instructionsd installationetGuided utilisationetd entretien Table of Contents Table des matières 2 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY IMPORTANT LIRE ET CONSERVER CES INSTRUCTIONS POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT LI30ZC W10487239D ...

Page 2: ...chever l installation 27 UTILISATION DE LA HOTTE 27 Commandes de la hotte de cuisinière 27 ENTRETIEN DE LA HOTTE 27 Nettoyage 27 SCHÉMAS DE CÂBLAGE 29 ASSISTANCE OU SERVICE 30 Au Canada 30 Accessoires 30 GARANTIE 31 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the ...

Page 3: ...ical wiring and other utilities Ducted fans must always be vented outdoors CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or into crawl spaces or garages WARNING TO REDUCE THE RISK OF F...

Page 4: ... model serial rating plate The model serial rating plate is located inside the liner behind the filter on the left wall of the range hood Range hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimensions that are shown must be used Given dimensions provide minimum clearance Consult your cooktop range manufacturer installation instr...

Page 5: ...ber of elbows should be kept to a minimum to provide efficient performance For the most efficient and quiet operation Use no more than three 90 elbows Make sure there is a minimum of 24 61 0 cm of straight vent between the elbows if more than 1 elbow is used Do not install 2 elbows together The vent system must have a damper Use clamps to seal all joints in the vent system Use caulking to seal ext...

Page 6: ...best performance use no more than three 90 elbows To calculate the length of the system add the equivalent feet meters for each of the vent pieces used in the system Example vent system 6 15 2 cm Non Vented recirculating Installations Through the Soffit Cabinet If it is not possible to vent cooking fumes and vapors to the outside the range hood can be used in the non vented recirculating version u...

Page 7: ...ion of the customer to have the properly grounded outlet installed by a qualified electrician The grounded 3 prong outlet is to be located inside the cabinet above the range hood at a maximum distance of 33 85 0 cm from where the power cord exits the hood The grounded 3 prong outlet must be accessible after installation of the range hood See illustration Electrical Shock Hazard Plug into a grounde...

Page 8: ...ts walls and or soffit Venting Outside Through the Roof Measure and mark the lines as shown Use a saber saw or keyhole saw to cut an opening through the top of the cabinet and the roof for the vent Go to Step 3 NOTE For 12 30 5 cm high cabinets a 6 deep x 8 wide 14 6 cm x 20 3 cm rectangular opening in the cabinet top is required for damper transition clearance Venting Outside Through the Wall Ins...

Page 9: ...w or keyhole saw to cut an opening for the vent For non vented recirculating installations only the range hood can be vented indoors through the top of the cabinet For non vented recirculating installations charcoal filters are necessary See the Range Hood Care section for instructions on installing charcoal filters The Recirculation Kit Part Number W10490330 must be used A Measurement A B Centerl...

Page 10: ...eeded insert spacers between each side of the canopy and the mounting plate to space and center the canopy in the cabinet Align the bottom of the canopy with the bottom of the cabinet Install four 4 2 x 19 mm screws into the round mounting plate openings and tighten all 8 mounting screws 3 For some installations A filler strip may be required for some cabinets Install a filler strip and secure wit...

Page 11: ...m Vented Installations 1 Connect the vent system to the range hood vent opening Seal the connection with clamps Non Vented recirculating Installations 1 Connect the vent system to the range hood vent opening Seal the connection with clamps 2 Install vent cover 3 Install charcoal filters See the Range Hood Care section To order replacement kits see the Assistance or Service section CompleteInstalla...

Page 12: ...rior surface do not use steel wool or soap filled scouring pads Always wipe dry to avoid water marks Cleaning Method Liquid detergent soap and water or all purpose cleanser Wipe with damp soft cloth or nonabrasive sponge then rinse with clean water and wipe dry Metal Grease Filter The filters should be washed frequently Place metal filters in dishwasher or hot detergent solution to clean Let filte...

Page 13: ...er Replacing a Halogen Lamp Turn off the range hood and allow the halogen lamp to cool To avoid damage or decreasing the life of the new bulb do not touch bulb with bare fingers Replace bulb using tissue or wearing cotton gloves to handle bulb If new lamps do not operate make sure the lamps are inserted correctly before calling service 1 Disconnect power 2 Push up on the lens and turn it countercl...

Page 14: ... Temp 45 1 37 7 30 3 28 8 73 4 F 23 C Y Y Y Y BK BK BK BK GY R W W BU BU W W Y G Y G Y G BR BR Mechanical Push Buttons 4 buttons 3 speeds W BR BK L 4 High Speed BR BU L 3 Med Speed BR W L 2 Low Speed BR Y L 1 Lamps No Connection Off POSITION FUNCTION SWITCH OPERATION Motor Chassis SE13BC 12 5uF Ground Common Min V Med V High V Max V W Y Y W S40 M ...

Page 15: ...ts sales Referrals to local dealers repair parts distributors and service companies Whirlpool Canada LP designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in Canada For further assistance If you need further assistance you can write to Whirlpool Canada LP with any questions or concerns at Customer eXperience Centre Whirlpool Canad...

Page 16: ...TY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW Some states and provinces do not allow limitations on the duration of implied warranties of merchantability or fitness so this limitation may not apply to you This warranty gives you specific legal rights and you also may have other rights that vary from state...