Operating Manual
SECTION 4
PROTEGE 5442P
17
112509 Rev G
4.
To move the platform downward, pump the handle while depressing the black
valve button located beside the hand pump.
5.
Return the hand pump handle to its bracket in the right-hand machinery cabinet.
6.
To manually override the lower gate lock, insert a 7/64” Allen Wrench into the
triangular recess in the hole below the lower gate stop bracket on the front of the
lift, then turn it about 1/8 turn counterclockwise. This will unlock the gate and
prevent the lift from operating. Return the lock override to its original position to
restore operation.
Manual Transportation
One person can push the lift on a hard, level, and smooth surface. Two people may be
required to push it on a carpeted surface.
Forklift Transportation
On surfaces other than those mentioned above, the lift should be moved by a forklift.
Set the forklift tine spacing at 24 inches [610 mm] outside-to-outside. (The forklift tine
spacing is marked on the lift, below the upper landing gate.) The forklift pickup points
are on the underside of the base at the upper landing end.
Do not
attempt to pick up
the lift from the lower landing end. The unit should be in its transport mode before lifting
it with a forklift.
WARNING!
Use extreme caution when rolling the lift up or down an incline, as it weighs
approximately 850 pounds. Always use at least two (2) people to move the lift
on an incline.