background image

 

 

 

OPERATING MANUAL

 

ASCENSION MAESTRO  

PORTABLE WHEELCHAIR LIFT 

MODEL 2040T 

OPERATING MANUAL

 

ASCENSION PROTEGE  

PORTABLE WHEELCHAIR LIFT 

MODEL 5442P 

Patented – see www.ascension-lift.com/patents 

By Philip Brobeck at 5:31 pm, Dec 20, 2018

Summary of Contents for 5442P

Page 1: ...OPERATING MANUAL ASCENSION MAESTRO PORTABLE WHEELCHAIR LIFT MODEL 2040T OPERATING MANUAL ASCENSION PROTEGE PORTABLE WHEELCHAIR LIFT MODEL 5442P Patented see www ascension lift com patents...

Page 2: ......

Page 3: ...OPERATING MANUAL ASCENSION PROTEGE PORTABLE WHEELCHAIR LIFT MODEL 5442P...

Page 4: ...Copyright 2018 Ascension a Division of AGM Tucson Arizona This document or parts thereof may not be reproduced in any form by any method for any purpose without the written permission of Ascension...

Page 5: ...rminology 5 Important Safety Information 6 Description of Operation 7 SECTION 2 9 Setup Instructions 9 SECTION 3 13 Operation 13 SECTION 4 14 Installing the Casters for Portability 14 Operating the Li...

Page 6: ......

Page 7: ...uickly set up for use when needed or put into storage when not needed The lift can be used at almost any stage or platform up to 42 inches 1060 mm high About This Manual This manual provides facility...

Page 8: ...ess https ascension lift com lift setup Getting Help If you have a question or problem with the lift review the troubleshooting guide in Section 5 of this manual as well as the comprehensive troublesh...

Page 9: ...sion Ascension s business hours are 8 a m to 5 p m Mountain Standard Time Monday through Friday Telephone 800 459 0400 Mailing Address Ascension Fax 520 881 4983 Customer Service Email sales ascension...

Page 10: ...minute 25 mm s Physical DIMENSIONS 48 wide x 49 high x 61 long 1220 x 1250 x 1550 mm WEIGHT 850 pounds 385 kg MATERIALS Platform base frame gates Mild steel Platform sheet metal safety pans Aluminum a...

Page 11: ...Cabinet The enclosures in which the lifting and control mechanisms are located There is one cabinet on each side of the lift The contents of the machinery cabinets are accessible through the access p...

Page 12: ...d cause the cord to become damaged resulting in electrical shock or fire hazard 6 Set up the lift for operation only in accordance with the instructions in Section 2 of this manual If the lift cannot...

Page 13: ...e left hand machinery cabinet This switch halts the movement of the platform when it reaches the upper landing and its adjustment must be confirmed every time the lift is relocated The motion of the p...

Page 14: ...is located in the right hand machinery cabinet The casters are stored in the left hand machinery cabinet They can quickly and easily be installed underneath the lift so that the lift can be moved to a...

Page 15: ...the disconnect switch to the ON position Raise the platform at least 12 inches 305 mm To do so turn the barrel key in the setup switch on the front of the lift and hold an operating switch up OR use...

Page 16: ...e 2 for identification of the adjustment tool 7 Use the adjustment tool to remove the magnetic optical reflector from the vertical guide rail To do so place the adjustment tool on the reflector turn i...

Page 17: ...t Steps 8 9 until it is correct 11 With the platform at the correct height use the height adjustment tool to reattach the reflector to the vertical guide rail Rest the adjustment tool in the u shaped...

Page 18: ...necessary until the platform stops at the correct height 13 Return the height adjustment tool to the tool holder in the left hand machinery cabinet 14 The lift is ready for use WARNING The lift s stop...

Page 19: ...any one of the three operating switches The operating switches must be held with constant pressure until the platform stops at the upper or lower landing Push the emergency stop button to activate it...

Page 20: ...inet and install them into the color coded sockets located at the corners of the platform underside See Figure 6 and Figure 7 The rigid casters marked yellow must be oriented so the lift will roll for...

Page 21: ...g switch down OR use the manual pump per Section 4 Operating the Lift Without Power Certain option packages incl universal key switches require manual operation 4 Unplug the electrical cord and coil i...

Page 22: ...ter access panel on the right hand machinery cabinet and remove it from its bracket 2 Swivel the pump linkage outward and then insert the hand pump handle into it Figure 8 3 To move the platform upwar...

Page 23: ...on Manual Transportation One person can push the lift on a hard level and smooth surface Two people may be required to push it on a carpeted surface Forklift Transportation On surfaces other than thos...

Page 24: ...roll or step onto the plywood The plywood needs to be very flat for the lift to operate correctly An extension cord may be used with the lift only in accordance with the instructions listed in the fol...

Page 25: ...ON The lift is set up on a level surface less than 5 Both gates are closed The lift will not operate if either one of the gates is open The emergency stop button on the passenger s operating station i...

Page 26: ...Operating Manual SECTION 5 PROTEGE 5442P 20 112509 Rev G NOTES...

Page 27: ......

Page 28: ...Printed in the U S A 112509 Rev G A DIVISION OF AGM...