Port Specifications
Appendix B
32
Aruba AP 80 Outdoor Wireless Access Point
0500125-03
Installation Guide
January 2006
AP 80 Power over Ethernet Injector Module
10/100BASE-TX Pin Assignments
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45
connections: 100-ohm Category 3 or better cable for 10 Mbps connections, or
100-ohm Category 5 or better cable for 100 Mbps connections.
N
OTE
:
Make sure that the combined length of any twisted-pair connection
between the Mobility Controller and the PoE injector, and the PoE injector
to the AP does not exceed 90 meters (295 feet).
The RJ-45 ENET port on the power injector is wired with MDI pinouts. This
means that you must use crossover cables for connections to PCs or servers, and
straight-through cable for connections to switches or hubs. However, when
connecting to devices that support automatic MDI/MDI-X pinout configuration,
you can use straight-through cabling.
White/Orange Stripe
Orange
White/Green Stripe
Green
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
8-Pin DIN
Female
RJ-45
1
7
2
3
4
5
8
6
White/Blue Stripe
White/Brown Stripe
Brown
Blue
8-Pin DIN Female
Front View
10/100BASE-TX MDI and MDI-X Port Pinouts
Pin
MDI-X Signal Name
MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)
4,5,7,8
Not used
Not used
Note: The “+” and “-” signs represent the polarity of the wires that make up each wire pair.