86
MDR User Guide
B Error Messages
Error Name
Error
Number
Error Message
Error Description
S_mdr_COMMBUF_TOO_SMALL 0x55500001
The TCP/IP
communication
buffer is too
small.
The MDR Server or the MDR Client is trying to send,
through the communication buffer, a buffer larger than
the communication buffer size.
S_mdr_COMM_OUT_OF_SYNCH 0x55500002
Communication
out of synchroni-
zation.
The MDR Client has received a response packet that
doesn’t match the expected response to the command
sent previously to the MDR Server.
S_mdr_COMM_INTERFACE_DOWN 0x55500003
Communication
interface down.
The communication interface is down
S_mdr_CURRENT_RECORDING_NOT_SET 0x55500004
The current re-
cording is not set.
There is no recording present in the recording table and
the MDR software expects the current recording to be
set.
S_mdr_DISK_ALREADY_IN_USE 0x55500005
Disk already in
use
The disk is already included in a disk group. It cannot
be included in two different disk groups at the same
time.
S_mdr_DISK_ERROR 0x55500006
MDR disk error.
The MDR Server is unable to write to the storage de-
vice.
S_mdr_DISK_GROUP_NOT_FOUND 0x55500007
Disk group not
found
The disk group cannot be found. The disk group name
may be invalid or some disks contained in the disk
group may be missing or unreachable.
S_mdr_DISK_GROUP_ALREADY_PRESENT 0x55500008
Disk group al-
ready present
The disk group with the same name is already present
on the FC loops.
S_mdr_DPIO_EEPROM_DAMAGED 0x55500009
DPIO EEPROM
damaged
The EEPROM of the DPIO is damaged.
S_mdr_DPIO_ERROR 0x5550000A
DPIO ERROR
DPIO error.
S_mdr_DPIO_NOT_PRESENT 0x5550000B
DPIO not present.
DPIO module is not installed in the MDR System and
the MDR Server has received a command that requires
the use of this DPIO module.
S_mdr_DPIO_OVERFLOW 0x5550000C
Overflow in FIFO
of DPIO device.
The data source is sending data faster than what the
DPIO input module is able to transfer. If the data path is
FPDP and the data source supports the Suspend signal,
then the configuration item
SuspendEnable
(section
DpioInfo
in the configuration file mdr.ini) should be
set to 1 (i.e. enabled).
S_mdr_ILLEGAL_OPERATION 0x5550000D
Illegal operation.
The current state does not allow the command. This
error is reported, for instance, when the MDR is re-
cording and receives in the same time another command
that involves a modification of the recording table.
S_mdr_INVALID_ARGUMENT 0x5550000E
Invalid argument.
At least one argument of the command is not valid.
S_mdr_INVALID_MEMORY_BLK_TBL 0x5550000F
Invalid Memory
Block Table.
The MDR Memory Block Table has not been initialized
correctly.
S_mdr_INVALID_MODEL_NAME 0x55500010
Invalid MDR
model name.
The MDR model name specified in the configuration
file
mdr.ini
is not valid.
S_mdr_INVALID_PARAMETER 0x55500011
Invalid parameter. An MDR Server / MDR API / MDR Shell function
parameter is not valid.
S_mdr_INVALID_RECORDER_BLK_TAG 0x55500012
Invalid recorder
block tag
The tag present inside the data of the recorder block is
invalid.
S_mdr_INVALID_RECORDING_NUMBER 0x55500013
Invalid recording
number.
The recording number specified is not valid. The re-
cording number must be a positive number, not null,
and lower or equal to the number of the last recording
present in the recording table.
S_mdr_INVALID_RECORDING_STATE 0x55500014
Invalid recording
state
The state of the recording is invalid. For instance, the
MDR Shell
copy disks host ./ 1
is executed
whereas the recording number 1 is not stored.
S_mdr_INVALID_USER_BLKSIZE 0x55500015
Invalid user block
size.
Reserved for future use.
S_mdr_MDR_INI_FILE_ERROR 0x55500016
MDR ini file
error.
The MDR Server / MDR API / MDR Shell is unable to
read an item (or its value) from the configuration file
mdr.ini.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com