The values of items
s1,s2,…sn
may specify the hostname(s) of one or several MDR
systems that the user want to control with the MDR shell program. In the above
example, only one MDR called
midas
is specified.
All hostnames/IP addresses in the
[Servers]
section have to be located in the hostname
database being used by the computer running the MDR shell. The MDR shell program
retrieves the IP address corresponding to the hostname for each host.
If the user specifies one or more server items in the
[Server]
section, then the MDR
shell will not prompt the user for the hostname of the MDR server before trying to
connect to the MDR server.
4.4 Configuring the MDR for Ethernet Operation
To configure an MDR-250-xxxxE unit with Ethernet operation, start up the MDR
system and then use the
bootChange
command to set the boot parameters as follows:
-> bootChange
‘.’ = clear field; ‘-‘ = go to previous field; ^D=quit
boot
device
:
mdc5
processor number
: 0
host
name
:
.
file
name
:
.
inet on ethernet (e)
: <Ethernet IP address>
inet on backplane (b)
: .
host inet (h)
: .
gateway inet (g)
: .
user
(u)
:
.
ftp password (pw) (blank = use rsh): .
flags
(f)
:
0x0
target name (tn)
: <Target name>
startup script (s)
: .
other
(o)
:
.
MDR User Guide
21