76
MDR User Guide
[
DpioInfo
]
This section contains information the MDR Server needs to know about the DPIO
modules installed on the MDR.
SuspendSignal
Disable
or
Enable
DPIO suspend signal. If this item is not defined then the default
value is
Enable
.
DPIO-InputUnits
Number of DPIO input units that are used. Currently, this value is limited to 0 (no
DPIO input PMC installed) or 1. If this item is not defined then the MDR Server
ignores the DPIO input modules and the items
DPIO-InputUnitXPmcSlot
presented
below.
DPIO-OutputUnits
Number of DPIO output units that are used. Currently, this value is limited to 0 (no
DPIO output PMC installed) or 1. If this item is not defined then the MDR Server
ignores the DPIO input modules and the following items
DPIO-
OutputUnitXPmcSlot
presented below.
DPIO-InputUnitXPmcSlot
PMC slot of DPIO input unit X. This value should be 1 (or 2 according to the MDR
standard configuration) for performance reasons. If the
DPIO-InputUnits
item is set
to 0 or not defined then this item is ignored. If this item is missing then the DPIO
input module X is ignored.
DPIO-OutputUnitXPmcSlot
PMC slot of DPIO output unit X, where X is a decimal number in the range 1-6. This
value should be 1 or 2 for performance reasons. If the
DPIO-OutputUnits
item is set
to 0 or not defined then this item is not used. If this item is missing then the DPIO
output module X is ignored.
StartInputWaitTime
M
aximum time the MDR server will wait before receiving the first recorder block of
data. The value of this item could be considered as the maximum time that the user
could use to launch the DPIO input stream. If this item is missing or set to –1 then the
MDR Server will wait forever at the beginning of the recording and never return,
provided there is no input data (the watchdog timer is disabled in this case).
InputWaitTime
Maximum time the MDR server will wait between two consecutive recorder blocks
of input data. The value of this item could be considered as the maximum time the
data stream can use to transfer a block of data in the recorder (its size is the
RecorderBlockSize value). If this item is missing or set to –1 then the MDR server
will wait forever during the recording and never return, provided there is no input
data (the watchdog timer is disabled in this case).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com