28
MDR User Guide
5.2.3 Installing the Fibre Channel QLogic Driver for Solaris
Install the VMFC2X00 module on your Solaris SPARC station or SBC.
5.2.3.1 Install the qla2X00 package
If the MDR project is not already installed, follow the instructions
in
section 4.2:
MDR
Shell and API Installation
.
Go to the directory called
mdr-host-sw/fibre-channel-drivers/sun-solaris
First you need to uncompress the file
qla2100_<VersionNumber>.zip
(if you have a
VMFC2100 board) or the image file
qla2200<VersionNumber>.zip
(if you have a
VMFC2200 board) on your Solaris SPARC station (or SBC) using the
unzip
tool.
Then you need to follow the instructions provided in the
readme.pdf
file.
As a summary:
•
Uncompress the image file
qla2100.Z
(if you have a VMFC2100 board) or the
image file
qla2200.Z
(if you have a VMFC2200 board) on your Solaris SPARC
station (or SBC) using the
uncompress
tool.
•
Become super-user.
•
Install the qla2x00 driver package with the command line:
pkgadd –d <path>/qla2100
or
pkgadd –d <path>/qla2200
and follow the prompts. The default answers for the questions the installation program
asks can be accepted. If the installation program asks to perform some actions, accept
them.
•
In the
/etc/driver_aliases
file, add the line
qla2100 “pci129a,2100”
if you
have a VMFC-2100(P) board or
qla2200 “pci129a,2200”
if you have a VMFC-
2200(P) board.
5.2.3.2 Prepare MDR Disk(s) for Solaris
•
Connect fibre-channel disk(s) to the VMFC-2X00 host card,
•
Use the
format
command and choose the appropriate disk, typically
“/dev/rdsk/c?t?d?”
,
•
Label the disk (
‘l’
command),
•
You may want to set the volume name (
‘v’
command), e.g. ‘
”MDR-Vol1”
’.
Note: This step is optional.
5.2.3.3 Running the MDR Shell
•
In order to access the MDR storage device via FC connection, the MDR Shell
program requires the administrator (or root) privileges. This is a requirement from
the Windows and Solaris operating systems, not the MDR software.
•
Set the
MDR_BASE
environment variable as shown in section 4.3:
Configuring the
MDR Shell.
•
Run the MDR Shell program and just press the Enter key when prompted for the
MDR server name.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com