BSP
COMX-P40x0 ENP2 Installation and Use (6806800R95B
)
98
The default active console is UART0. The working mode is 115200, 8, N, 1. Each of the four
UART can become the active console by setting the environment variable "uart#".
The UART boot up message in U-Boot is as follows:
7.13 NOR Flash
The NOR Flash is Numonyx™ Axcell™ JS28F00AM29EWL or Spansion S29GL01GP11TFIR2 and
is attached to the GPCM on local bus and works with 16-bit data width. It is either 1 GB or 128
MB and has 1024 uniform blocks of 128 K (or 64 K words each). The 36-bit physical address of
NOR Flash is 0xFE8000000 - 0xFEFFFFFFF. Boot up message in U-Boot is "FLASH: 128 MiB".
NOR Flash supports the following commands: md, cp, cmp, protect and erase.
Usage:
UART0
-
setenv uart# 0; saveenv; reset
UART1
-
setenv uart# 1; saveenv; reset
UART2
-
setenv uart# 2; saveenv; reset
UART3
-
setenv uart# 3; saveenv; reset
In :
Serial
Out :
Serial
Err :
Serial
Current Console:
uart#0
Table 7-6 NOR Flash Command Usage
Command
Description
protect on start end
Protects flash from address "start" to address "end"
protect on start +len
Protects flash from address "start" to end of section with address
"start"+"len"-1
Summary of Contents for COMX-P40x0 ENP2
Page 1: ...COMX P40x0 ENP2 Installation and Use P N 6806800R95B August 2014...
Page 8: ...COMX P40x0 ENP2 Installation and Use 6806800R95B 8 List of Tables...
Page 10: ...COMX P40x0 ENP2 Installation and Use 6806800R95B 10 List of Figures...
Page 26: ...Introduction COMX P40x0 ENP2 Installation and Use 6806800R95B 26...
Page 56: ...Controls LEDs and Connectors COMX P40x0 ENP2 Installation and Use 6806800R95B 56...
Page 78: ...Functional Description COMX P40x0 ENP2 Installation and Use 6806800R95B 78...
Page 126: ...Related Documentation COMX P40x0 ENP2 Installation and Use 6806800R95B 126...
Page 128: ...COMX P40x0 ENP2 Installation and Use 6806800R95B Safety Notes 128...
Page 129: ......