U-Boot provides "usb" utilities to operate the USB sticks:
Note that "usb start/reset" must be executed before the other commands can be run. Below
are usage samples of "usb start.
7.19 SerDes
The COMX-P40x0 has three Serializer/Deserializer (SerDes) banks, including a total of 18 lanes.
For more information on the SerDes, see
. This includes the SerDes
lane distribution and options when it is routed to the COM-E connectors.
Utility
Function
usb reset
Resets or rescans USB controller
usb stop [f]
Stops USB [f]=force stop
usb tree
Shows USB device tree
usb info [dev]
Shows available USB devices
usb storage
Shows details of USB storage devices
usb dev [dev]
Shows or set current USB storage device
usb part [dev]
Prints partition table of one or all USB storage devices
usb read addr blk# cnt
Reads `cnt' blocks starting at block `blk#' to memory address
`addr‘
usb write addr blk# cnt Writes `cnt' blocks starting at block `blk#' from memory
address `addr'
=> usb start
(Re)start USB...
USB: Register 10011 NbrPorts 1
USB EHCI 1.00
scanning bus for devices... 3 USB Device(s) found
scanning bus for storage devices... 1 Storage Device(s) found
Summary of Contents for COMX-P40x0 ENP2
Page 1: ...COMX P40x0 ENP2 Installation and Use P N 6806800R95B August 2014...
Page 8: ...COMX P40x0 ENP2 Installation and Use 6806800R95B 8 List of Tables...
Page 10: ...COMX P40x0 ENP2 Installation and Use 6806800R95B 10 List of Figures...
Page 26: ...Introduction COMX P40x0 ENP2 Installation and Use 6806800R95B 26...
Page 56: ...Controls LEDs and Connectors COMX P40x0 ENP2 Installation and Use 6806800R95B 56...
Page 78: ...Functional Description COMX P40x0 ENP2 Installation and Use 6806800R95B 78...
Page 126: ...Related Documentation COMX P40x0 ENP2 Installation and Use 6806800R95B 126...
Page 128: ...COMX P40x0 ENP2 Installation and Use 6806800R95B Safety Notes 128...
Page 129: ......