Chapter 2
COMX-P40x0 ENP2 Installation and Use (6806800R95B)
27
Hardware Preparation and Installation
2.1
Environmental and Power Requirements
2.1.1
Environmental Requirements
The following module environmental requirements must not be exceeded.
The following table provides the environmental requirements for the module.
Thermal Requirements
A standard passive heat sink can be provided by Artesyn; 12 CFM system airflow volume (at
71
o
C) is needed for the heat sink to keep sufficient cooling to the module. Contact your
Artesyn sales representative for detailed thermal information.
Operating temperature refers to the temperature of the air circulating around the module
and not the component temperature.
Table 2-1 Environmental Requirements
Requirement
Operating
Non-Operating
Temperature
-40°C to +71°C
-50°C to +100°C
Humidity
to 100% RH
to 100
% RH
Vibration Sine (10mins/axis)
5G, 15 to 2000Hz
Vibration Random (1hr/axis)
0.04g2/Hz, 15 to 2000Hz
(8GRMS)
Shock
30g/11mS(half sine)
Altitude
-60 to 4000 m ASL
Summary of Contents for COMX-P40x0 ENP2
Page 1: ...COMX P40x0 ENP2 Installation and Use P N 6806800R95B August 2014...
Page 8: ...COMX P40x0 ENP2 Installation and Use 6806800R95B 8 List of Tables...
Page 10: ...COMX P40x0 ENP2 Installation and Use 6806800R95B 10 List of Figures...
Page 26: ...Introduction COMX P40x0 ENP2 Installation and Use 6806800R95B 26...
Page 56: ...Controls LEDs and Connectors COMX P40x0 ENP2 Installation and Use 6806800R95B 56...
Page 78: ...Functional Description COMX P40x0 ENP2 Installation and Use 6806800R95B 78...
Page 126: ...Related Documentation COMX P40x0 ENP2 Installation and Use 6806800R95B 126...
Page 128: ...COMX P40x0 ENP2 Installation and Use 6806800R95B Safety Notes 128...
Page 129: ......