Power Requirements
This board is designed to operate with the input voltages and currents as defined in the
following tables.
2.2
Unpacking and Inspecting the Enclosure
Read all notices and cautions prior to unpacking the product.
Table 2-3 Current Drawn
State
12v
VCC_RTC
Idle
2.81A
100 uA
Full Loading (Linux)
2.91A
100 uA
Table 2-4 COMX-P4080-4G-E-ENP2
Volts
Amps
Power
12
2.6
31.2
Total Power dissipation (W)
31.2
Damage of Circuits
Electrostatic discharge and incorrect installation/removal of the product can damage
circuits or shorten their life.
Before touching the product make sure that you are working in an ESD-safe
environment with protective equipment such an ESD wrist strap and ESD shoes. Hold
the product by its edges and do not touch any components or circuits.
Summary of Contents for COMX-P40x0 ENP2
Page 1: ...COMX P40x0 ENP2 Installation and Use P N 6806800R95B August 2014...
Page 8: ...COMX P40x0 ENP2 Installation and Use 6806800R95B 8 List of Tables...
Page 10: ...COMX P40x0 ENP2 Installation and Use 6806800R95B 10 List of Figures...
Page 26: ...Introduction COMX P40x0 ENP2 Installation and Use 6806800R95B 26...
Page 56: ...Controls LEDs and Connectors COMX P40x0 ENP2 Installation and Use 6806800R95B 56...
Page 78: ...Functional Description COMX P40x0 ENP2 Installation and Use 6806800R95B 78...
Page 126: ...Related Documentation COMX P40x0 ENP2 Installation and Use 6806800R95B 126...
Page 128: ...COMX P40x0 ENP2 Installation and Use 6806800R95B Safety Notes 128...
Page 129: ......