Platform Architecture
AXP640 Installation and Use (6806800M24F)
45
The implementation of the interface is indicated by the level of PICMG compliance a blade or
hub is designed. The AXP640 supports the PICMG 3.1 fabric standard to allow for several
configuration options that can provide greater bandwidth to certain slots in the shelf. The
fabric interface supports: PICMG 3.1 Option 9 (10Gbps).
1.4.3
IPMI Network
The Intelligent Platform Management Interface (IPMI) is based on a redundant radial topology.
Redundant IPMI networks are supported by the Shelf Management Alarm Module (SAM) to
manage the shelf resources.
The SAM is the center of the IPMI network. The SAM connects to all slots in the shelf and
monitors and reports on the content of the AXP640. The SAM collects environmental data
from sensors within the shelf and can assist high availability software to determine when a
failover is necessary due to hardware removal or environmental changes, such as an over-temp
condition.
The SAMs contain the Shelf Management Controller (ShMC) which polls all devices resident to
the shelf and collects the FRU data records for all the components. The SAM also manages non-
IPMI devices for the shelf and performs environmental monitoring of the temperature and
voltage. Using the PICMG 3.0 standard, the SAM is able to power off and reset slots for hot swap
capability.
Summary of Contents for AXP640
Page 1: ...AXP640 Installation and Use P N 6806800M24F May 2014 ...
Page 8: ...AXP640 Installation and Use 6806800M24F Contents 8 Contents Contents ...
Page 10: ...AXP640 Installation and Use 6806800M24F 10 List of Tables ...
Page 50: ...Platform Architecture AXP640 Installation and Use 6806800M24F 50 ...
Page 70: ...AXP640 Shelf Description AXP640 Installation and Use 6806800M24F 70 Figure 2 14 AC Inlet 220V ...
Page 101: ...Site Preparation AXP640 Installation and Use 6806800M24F 101 Figure 3 13 Planning Checklist 2 ...
Page 102: ...Site Preparation AXP640 Installation and Use 6806800M24F 102 ...
Page 112: ...AXP640 Operations AXP640 Installation and Use 6806800M24F 112 ...
Page 136: ...AXP640 Shelf Installation AXP640 Installation and Use 6806800M24F 136 ...
Page 164: ...FRU Installation AXP640 Installation and Use 6806800M24F 164 ...
Page 186: ...Shelf Management Alarm Module AXP640 Installation and Use 6806800M24F 186 ...
Page 189: ......