Shelf Management Alarm Module
AXP640 Installation and Use (6806800M24F)
177
The FPGA device contains a built-in CRC error checker for detecting soft errors in the
configuration data. When a CRC error is detected the signal LATCH_CRC_ERROR is set active by
the ShMM-1500R CRC error detection circuit, which immediately sets the
ShMM_STATUS[0:1]_L and ACTIVE# signals high. The peer ShMM-1500R, if it is not already
active upon detecting the loss of the status serial bit streams, becomes the active ShMM-
1500R.
The HRI also includes 13 test points for in-service monitoring of the hardware redundancy
signals and for out-of-service diagnostics, enabling the ShMM-1500R to isolate failures on the
HRI to a single cShMM-1500R pair.
7.5.2.2
HRI Protocol
In the redundant configuration, the two ShMM-1500R boards communicate through the HRI
by exchanging data packets. The HRI continues to be operational in case of a single
interconnection failure and is able to detect a double failure. The HRI has a redundant
communication path, using four signals. In the case of a single wire permanent failure (the
signal gets stuck high, low or breaks), data packets continue to be transmitted through the
redundant communication path. A short between two of these four signals is considered a
double failure.
Figure 7-3
SAM HRI Interconnection
Summary of Contents for AXP640
Page 1: ...AXP640 Installation and Use P N 6806800M24F May 2014 ...
Page 8: ...AXP640 Installation and Use 6806800M24F Contents 8 Contents Contents ...
Page 10: ...AXP640 Installation and Use 6806800M24F 10 List of Tables ...
Page 50: ...Platform Architecture AXP640 Installation and Use 6806800M24F 50 ...
Page 70: ...AXP640 Shelf Description AXP640 Installation and Use 6806800M24F 70 Figure 2 14 AC Inlet 220V ...
Page 101: ...Site Preparation AXP640 Installation and Use 6806800M24F 101 Figure 3 13 Planning Checklist 2 ...
Page 102: ...Site Preparation AXP640 Installation and Use 6806800M24F 102 ...
Page 112: ...AXP640 Operations AXP640 Installation and Use 6806800M24F 112 ...
Page 136: ...AXP640 Shelf Installation AXP640 Installation and Use 6806800M24F 136 ...
Page 164: ...FRU Installation AXP640 Installation and Use 6806800M24F 164 ...
Page 186: ...Shelf Management Alarm Module AXP640 Installation and Use 6806800M24F 186 ...
Page 189: ......