4. Ensure that the top and the bottom handles of the RTM are in an outward position
by squeezing the lever and the latch together.
5. Insert the RTM into the shelf by placing the top and bottom edges in the card guides
of the slot.
6. Slide the RTM into the slot.
7. Apply equal and steady pressure to the RTM to carefully slide the RTM into the shelf
until you feel resistance. Continue to gently push the RTM until the RTM connectors
engage.
8. Squeeze the lever and the latch together and hook the lower and the upper handle
into the shelf rail recesses.