Supported IPMI Commands
ATCA-7540 Installation and Use (6806871A01A)
257
Response Data
1
Completion Code. Generic plus the following command-specific
completion codes:
80h = feature selector not supported.
2
LSB of Artesyn IANA Enterprise Number. A value of CDh shall be
used.
3
2nd byte of Artesyn IANA Enterprise Number. A value of 65h shall be
used.
4
MSB of Artesyn IANA Enterprise Number. A value of 00h shall be
used.
5
Feature Configuration.
Bit [7-0]: Feature Selector = E0h, E1h
00h = disabled
01h = enabled
02h - 0ffh = reserved
Bit [7-0]: Feature Selector = 03h
00h-FFh: Debounce timer timeout value in 100 ms
6
Persistency / Duration
Table 8-26. Get Feature Configuration Command (continued)
Type
Byte Data
Field