The fire goes out
or the stove stops
automatically
1. The pellet tank is empty
2. No power
3. Pellets not being fed
4. Excessive deposit of ashes
in the grate
5. Intervention probe tem-
perature safety of the pellet
6. Cochlea blocked by dirt
7. The door is not closed
properly or gaskets worn
8. Pellet inadequate
9. Low pellet
10. Chimney or drain
clogged with nests or foreign
bodies
11. Pressure switch cuts
12. Smoke extraction motor
failure
13. Alarm active
1. Fill the tank with pellets
2. Check plug and presence electricity
3. Fill the tank with pellets
4. Clean the brazier
5. Let the stove cool down completely, reset
the manual reset and restart the stove. If the
problem persists, contact your authorized
service representative
6. Pull the plug, empty the tank, remove any
foreign objects
7. Close the door or replace the gaskets with
original
8. Change the type of pellet recommended
by the manufacturer.
Sometimes, depend-
ing on the type, the stage of adjustment
of the parameters need to vary the level
relating to the loading of pellets
9. Increase the level in the parameter for the
pellet feed.
To check the flow of fuel from
technical authorized
10. Eliminate all foreign matter from the
chimney Clean the smoke duct. Perform peri-
odic cleaning.
11. Verify potential smoke duct is blocked
and if the pressure switch is working
properly
12. Check and replace the motor if necessary
13. See paragraph alarms
The air fan conven-
tion (ambient air)
never stops
1. Temperature sensor tem-
perature control defective or
broken
2. Smoke probe fails
1. Check the operation of the sensor and
replace if necessary
2. Replace smoke probe
The stove does not
light.
1. Lack of electricity
2. Probe pellets in bulk
3. Fuse blown
4. Pressure switch broken
(lockout indicated)
5. Smoke outlet or duct
clogged
1. Check that the electrical outlet is plugged
in and the power switch to "I"
2. Lockout by resetting the rear thermostat,
replace the thermostat
if it happens again
3. Replace the fuse
4. Replace the pressure
5. Clean the smoke outlet and / or smoke
duct
Never turn off the heater by removing electricity. Let always complete the
shutdown cycle, otherwise you may damage the structure and have trouble
lighting in the future.
Summary of Contents for HERMETIC 10
Page 21: ...IT 21 Schema connessioni elettriche universale aria...
Page 43: ...EN 21 General diagram of the electrical air connections...
Page 65: ...21 FR Sch ma g n ral des connexions lectriques de l air...
Page 87: ...21 DE Allgemeines Schema der elektrischen Luftanschl sse...
Page 109: ...21 NL Algemeen schema van de elektrische luchtaansluitingen...