26/08/2021 v.1.10
ArSilicii s.r.l.
6
Custom System Logic
System Logic can be customized for special needs by the user, reprogramming the unit through a
serial communication programmer. For information ask directly to ArSilicii s.r.l. Examples of custom
system logic:
Manage batteries with special chemistry, 24V-12V Voltage system converter, Power Filtering and
Stabilizing, Solar power Converter/Charger, special logic by handling signal and/or analogic measure
through connector D.
FRONT LEDS
These units are provided with 4 front LEDs to signal the state.
LED LABEL
LED state
Description of the State
Charge
Off (Not lit)
Unit is not powered
Blinking Green or
Orange
System check and Charging
Blinking Red
Limit Reached (i.e. max temperature)
Steady
Supply
Fault
Off (Not lit)
Flashing Red
Call Assistance.
Battery
Green
Battery Full.
Orange
Battery medium charge.
Red
Battery Empty.
Bus Status
Flashing Green
Communication OK
Flashing Red
Communication Problems
CONNECTORS
The drawing above show a schematic diagram of the connectors designated in red. Below follow
the tables with the details for each connector and the functional description.