S
ig
n
a
l C
o
n
n
e
c
ti
o
n
s
69
Mscope HD422 Setup (Standard Mode)
Set "Frame Rate" up to 25PsF.
•
Set "HD-SDI Mode" to
•
Mscope HD422.
• Set the recording system input format to
4:2:2 YCbCr 1080PsF/i dual stream using
the frame rate set on the camera.
Connect link A of the configured output
•
board to recording input HD-SDI IN A.
Connect link B of the configured output
•
board to recording input HD-SDI IN B.
Connect recording HD-SDI monitor out to
•
control monitor input HD-SDI IN A or B.
Note:
HD-SDI output boards set to Mscope require
link A and B for signal output. Always use link
A and B from the same output board.
Note:
Standard Mode setup assigns the same settings to all
HD-SDI output boards. Individual configuration of the
output boards requires Advanced Mode setup.
Note:
Mscope is intended for use with anamorphic lenses.
The full sensor area with a 4:3 aspect ratio is output as
a 1920 x 1440 image using a dual stream signal. Each
link contains 1920 x 720 lines of the frame. A display
connected to one camera link or the recorder's monitor
OUT will display a de-squeezed preview image.
Note:
Dual stream/dual camera recording is commonly used for
stereoscopic capture with two camera heads. Please refer
to the recording system’s user manual for information and
instructions on 4:2:2 dual stream/dual camera recording.
Note:
For more information on Mscope, see the
glossary in chapter 17: Appendix.
B
A
C
on
tro
l M
on
ito
r
HD-SDI
IN
MONITOR
HD-SDI OUT
B
A
R
ec
or
di
ng S
ys
te
m
B
A
HD-SDI 2
B
A
HD-SDI 1
ARRIFLEX D-21
B
A
HD-SDI
OUT
Input Format:
4:2:2 Dual Stream
25p/50i
HD-SDI
IN
On Screen Menu:
25 PsF
Mscope HD422
Normal Range
Camera Display:
∢
180.0
fps 25.000