35
Multifunction LCD Digital Timer/Counter/Tachometer
Total Operation
TC-Pro48 has a total counter, separate from the 1-stage present counter, for counting the total accumulated
value.
the total counter continues to
count the total accumulated
value when the present
value is reset using reset/
reset 1 input (reset key).
the total count value is reset
when the total reset/reset
2 input is turned ON. If the
reset key is pressed while
the total count value is reset.
The present value is also
reset at this time.
the counting range of the
total counter is -99,999 to
999,999 (-999 to 9,999). The
total count value returns to 0
when it reaches the full scale
limit.
◆
◆
◆
Batch Counter Operation
TC-Pro48 has a batch counter, separate from the 1-stage present counter, for counting the number of times
the count value returns to 0 when it reaches the full scale limit.
The batch counter continues
after count completion.
Batch output is held until
batch counter reset is input.
When the batch counter
reset input is turned ON, the
batch count value is reset,
and batch output turns OFF.
If the reset key is pressed
while the batch count value
is displayed, the batch count
value is displayed, the batch
count value is reset and
batch output turns OFF. The
present value is also reset at
this time.
◆
◆
◆
◆
Note:
The batch count value is held at 0 during batch counter reset input.
If the batch count set is 0, batch count will be performed but there will be no batch output.
The batch count value returns to 0 when it reaches 999,999.
Once batch input has been turned ON, it will return to the ON state after power interruptions.
If the batch count set value is changed from a value that is greater than the batch count value to one that
is less, batch output will turn ON.
■
■
.
2
.
3.
4.
5.
Summary of Contents for TC-Pro482CRA
Page 1: ...Ver 3 0...
Page 56: ...Comparison Table...