7
Multifunction LCD Digital Timer/Counter/Tachometer
2-Stage Timer Function
2-stage Function Setting
Power ON
For details on operation in run mode, refer to page 18.
Note:
1. If the mode is switched to the 2-stage timer function setting mode during
operation, operation will continue.
2. Changes made to settings in function setting mode are enabled for the first
time when the mode is changed to run mode, the timer is reset (time initialized
and output turned OFF).
Set Forecast/Absolute Value
with
key
(Forecast value) (Absolute value)
Set time range with key
for details, refer to time range list
Set the output mode with key
(A) (F-1)
Set the input signal width with key.
(20ms) (1ms)
Set the NPN/PNP input mode with key
(NPN input) (PNP input)
Set the K/P level with key.
(KP-1) (KP-2) (KP-3)
(KP-4)
(KP-5)
See note 1
3s min.
See note 2
3s min.
Forecast/
Absolute
value
time range
output mode
input signal
width
NPN / PNP
input mode
K/P level
Run mode
2-staget timer function setting mode
Time range list
Display
Set Value
0.01s ~ 9999.99s (default)
0.1s ~ 99999.9s
1s ~ 999999s
0min 01s ~ 9999min 59s
0.1min ~ 99999.9min
1min ~ 999999min
0h 01min ~ 9999h 59min
0.1h ~ 99999.9h
1h ~ 999999h
0.001s ~ 999.999s
■