20
Multifunction LCD Digital Timer/Counter/Tachometer
Counter Function
Power ON
Run mode
1-stage counter function setting mode
See note 1
See note 2
3s min.
See note 3
See note 6
3s min.
For details on operation in run mode, refer to page23.
Note:
1. If the mode is switched to counter function setting mode during operation,
operation will continue.
2. Changes made to settings in function setting mode are enabled for the first
time when the mode is changed to run mode, the counter is reset(the preset
value is initialized and output turned OFF).
(See note 3) when using as a dual counter:
Dual counter calculating mode
Note: Displayed for output modes other than K-2, D, L and H only.
See note 4 See note 4
Note: displayed for output modes other than K-2, D, L and H only.
(UP) (DOWN) (UP/DOWN A) (UP/DOWN B) (UP/DOWN C)
Note: Displayed only when the output mode is C, R, K-1, P, Q, A or K-2.
(000.001s) (000.005s) (099.990s) (999.999s)
(000.001)
(001.000)
(999.999)
See note 5
See note 5
Note 5: displayed only when the input mode is UP/DOWN A, B or C.
(N) (F) (C) (R) (K-1) (P) (Q) (A) (K-2) (D) (L) (H)
(30Hz) (5KHz)
(20ms) (1ms)
(no decimal point) (one digit after
decimal point)
(two digit after
decimal point)
(three digit after
decimal point)
(NPN input) (PNP input)
(K-1)
(K-2)
(K-3)
(K-4)
(K-5)
(See note 6) when using as a 2-stage counter :
when using as a batch counter :
One-shot output 2 time
One-shot output 1 time
One-shot output 2 time
Note: Displayed only when the output
mode is C, R,K-1,P,Q,A or K-2.
(000.001s) (000.500s) (999.999s)
(000.001s) (000.500s) (999.999s)
(HOLD) (000.001s) (999.999s)
Input mode
Output mode
Counting
speed
Decimal point
position
Prescale value
Key protection
level
One-shot
output mode
Input signal
width
NPN / PNP
input mode