54
Step16
Use
key to select Chain.
►
Chain: Off
Step17
Use Entry keys or the knob to input 0 (it is chained to itself to
realize continuous execution). Press
key to confirm and
save the Chain value in EEPROM assigned by the sequence
number.
►
Chain: 0
Step18
Press
key to exit sequence operation menu.
0.000V 0.000A
0.000A CCH OFF
For the above operating procedures, the corresponding SCPI commands should be:
LIST:NUMB
0
;
Recalls the number 0 sequence
LIST:EDIT 1,CCL,1A,2S
;
Modifies the time of Step1 to 2S
LIST:ADD
CCH,5A,1S
;
Add CCH
,
5A, 1S to the last step
LIST:INS
3,CRL, 1
Ω
,10S
;
Inserts the third step
LIST:DEL
2
;
Deletes the second step
LIST:CHA
0
;
Chians itself
LSIT:SAVE
;
Saves list
LIST
ON
;
Enables list operation
LIST
OFF
;
Disables list operation
4.8.3 Starting/Stopping the List
Example 1: Start the No.0 sequence, and stop the active sequence operation.
Steps Operation
Descriptions
Display
Step1
Press
key +
key to enter into sequence operation menu.
►
No.: 1
Memo:
Step2
Use Entry keys or knob to set the sequence number (No.) to 0, and
press
key to confirm (recall the sequence in EEPROM
assigned by the sequence number).
►
No.: 0
Memo: Test Power
Step3
Press
key to exit sequence operation menu.
0.000V 0.000A
0.000A CCH OFF
Step4
Press
key +
key to activate sequence operation.
0.000V 0.0000A
1.0000A
L
CCL ON
Step5
Press
key +
key to stop sequence operation.
0.000V 0.000A
0.000A CCH OFF
For the above steps, the corresponding SCPI commands should be:
LIST:
NUMB
0
;
Recalls the number 0 sequence
LIST
ON
;
Starts sequence operation
LIST
OFF
;
Stops sequence operation