![Array electronic 3720A Manual Download Page 55](http://html1.mh-extra.com/html/array-electronic/3720a/3720a_manual_2975639055.webp)
52
15
The five sequence steps have been edited, and there is no need
to edit the step6. Press
key to exit step edit screen and
save the sequence data in EEPROM assigned by the sequence
number.
06. 0.00000s
CRH 20.000
Ω
16
Use
key to select “Count”; use Entry keys or the knob
together with
,
keys to input “5”. Press
key to
confirm and save the Count value in EEPROM assigned by the
sequence number.
Data:<New/Edit>
►
Count: 5
17
Use
key to select “Chain”; use Entry keys (the “Chain”
is OFF when the Entry key exceeds 6) or the knob to input
“Off”. Press
key to confirm and save the Chain value in
the EEPROM assigned by the sequence number.
►
Chain:Off
18
Press
key to exit sequence operation menu.
0.000V 0.000A
0.000A CCH OFF
19
Press
key +
key to activate sequence operation.
0.000V 0.0000A
1.000A
L
CCL ON
20
Press
key +
key to stop sequence operation.
0.000V 0.000A
0.000A CCH OFF
For the above operating procedures, the corresponding SCPI commands should be:
LIST: NUMB 0
;
Recalls the number 0 sequence
LIST:MEMO
“Test Power”
;
Sequence memo is “Test Power”
LIST: ADD
CCL,1A,1S
LIST: ADD
CCH,2A,1S
LIST: ADD
CV,1V,1S
LIST: ADD
CRL,1
Ω
,1S
LIST: ADD
CRH,200
Ω
,1S
;
The above 5 commands are sequence steps
LIST:COUNT
5
;
Cycle times for this sequence
LIST:CHA OFF
;
Disables the chained sequence
LIST
ON
;
Activates sequence operation
LIST
OFF
;
Stops sequence operation
4.8.2 Modifying, Adding, Inserting, Deleting the List
Exampel 1: Based on the example1 in 4.8.1 section, the step 1 modify the time to 2s. Add “CCH,
5A, 1S” to the last step. Insert “CRL , 1
Ω
,10S” at step3. Delete step2. The sequence is chained to
itself to realize the continuous execution.
Steps Operation
Descriptions
Display
Step1
Press
key +
key to enter into sequence operation
►
No.: 0
Memo: Test Power