9. Applied standards, certifications, declaration of conformity
refrigerated cabinets described in this manual meet the essential safety, hygiene, and protection
requirements established by the following European directives and laws:
Directive
Harmonised standards applied
Machinery Directive - 2006/42/EC
ISO/TR 14121; EN ISO 12100; EN 378-2;
EN 378-3; EN 378-4; EN 60079-10-1
Electromagnetic compatibility 2014/30/EU
EN 61000-3-2; EN 61000-3-3; EN 61000-3-11;
EN 55014-1; EN 55014-2
Low voltage 2014/35/EU
EN 60335-1; EN 60335-2-89/A2
RoHs Directive 2011/65/EC
(restricted use of certain hazardous substances
in electrical and electronic equipment)
EN 50581
European Regulation EC-1935/2004
(on materials intended for contact with the
goods)
EN 1672-1; EN 1672-2
i
Compliance with the requirements and standards are present in the generic facsimile of the
Declaration of Conformity at the end of this manual.
These models are excluded from the scope of the Directive 2014/68/EU in accordance with
article 4 paragraph 3 (and/or article 1 paragraph 2 letter f).
The performance of these refrigerated cabinets was determined through tests conducted in compli
-
ance with the standard
EN ISO 23953 - IEC/EN 60335-2-89
at the environmental conditions of climate class 3 (25 °C , 60%
R.H.) with safety test at 32°C +/-2°C see table:
Climatic Class of the
testing chamber
Temperature
dry bulb
Moisture
Humidity
Dew
point
Weight of water va
-
pour in dry air
°C
%
°C
g/kg
0
20
50
9.3
7.3
1
16
80
12.6
9.1
2
22
65
15.2
10.8
3
25
60
16.7
12.0
4
30
55
20.0
14.8
6
27
70
21.1
15.8
5
40
40
23.9
18.8
7
35
75
30.0
27.3
8
23.9
55
14.3
10.2
The weight of water vapour in dry air is one of the main factors that affects the performance and
power consumption of the counters.
Declaration of
conformity
A copy of the conformity statement is attached to the cabinet.
If the original copy of the Declaration of Conformity supplied with the unit is
lost, download a copy by filling out the form found in the footer of the home
page of the website
www.arneg.it
under "