installation &
operating instructions
Design Envelope
4300
&
4380
Vertical In-line Pumping Unit
12
Analog input
Programmable
analog voltage input
1
Voltage level
0:10
Vdc
Input resistance
Rin
10
K
Ω
Resolution
12
bit
Programmable
analog current inputs
1
Current range
0:20
mA
Input resistance
Rin
500
Ω
Relay Output
Programmable relay
output
2
(
n.o. n.c. com
)
Max terminal load
250
Vac
2
A
500
VA
Externals
Enclosure
ip55
Vibration test
ec 60068-2-6
Max relatively
humidity
95% (iec 60068-2-3)
Operating ambient
temperature
0:40°c
Storage ambient
Temperature
- 25°c:60°c
Min. ambient
temperature at full
operation
0°c
Altitude
0 - 3000
m, de-rate
1%
per
100
m
above
1000
m
Compliance with Standards
en 61800-3:2004
Adjustable speed electrical power
drive systems.
emc
requirements
iec 61800-5-1
Adjustable speed electrical drive sys-
tems -
part 5-1:
safety requirements
- electrical, thermal and energy
en 60204-1
Safety of machinery - electrical
emc
equipment of machines-
part 1
: gen-
eral rules
2.3 electrical installation
2.3.1 power wiring
fig 2.3.1
Upper right corner of the motor. Use Access port
#1
for power wiring and ground.
pin1
l1
l1
power supply
pin2
l2
l2
power supply
pin3
l3
l3
power supply
2.3.2 tools you will need
Access1
Access2
Ground
l3
Access
1
Access
2
l2
l1
2.5 &