16
On / Off
Provisioning
Button
10 s hold = Battery Reset
30 s hold = Clear Provisioning
5x = Initiate Publishing
Maintenance and Service
ON/OFF Switch Functions
The power switch is a small white toggle on the left side of the
internal board. It controls the unit’s power and must be toggled
to “on” or up for the unit to operate and function. Shown in “off”
position below.
Provisioning Button
The provisioning button is located on the bottom of the board
inside the ST6700. It has multiple functions based on how
many times it is pressed or held. The button is highlighted to
the right.
• Resetting Battery Life
One function of the provisioning button is resetting
battery life after changing the battery. Press and hold the
provisioning button for 10-15 seconds and battery life will
be reset in the unit.
• Resetting Provisioning
To clear all provisioning, press and hold the provisioning
button for 30-35 seconds.
• Initiate Publishing
To allow broadcasting on all channels during setup
press and release the provisioning button 5 times. It is
important not to press and release it too fast or too slow.
The procedure should be completed in a timeframe of
approximately 2-4 seconds.