14
Locate the end of the second cable (grey with black line) which is attached to the rear of the sensor
(cable end has connector fitted, length is 750mm). The cable can be slid into the upper grommet (which
is pre-slit) & fed through the lid.
Plug this cable into either one of the two connectors on the PCB. The lid can now be closed, ensure the
grommet is pressed into the lid. Check that no cables are trapped under the lid, make sure the lid seal
is in place, and then refit the 4 retaining screws.
A pair of self-adhesive Velcro-type pads are provided. Attach one to the side of the PSU case & the other
to a suitable location on the rear of the mounting panel.
Note: ensure the selected location does not stretch/stress the cables. Consideration should also be
given to keeping the PSU case within easy reach/access for maintenance staff. Fasten the PSU case
to the mounting panel.
This completes the behind-panel installation work.
IMPORTANT: Ensure terminal block screws are firmly tightened & clamp the wires securely.
Note earth connection is not required to PCB
IMPORTANT: Leave the sensor protective sticker in place for at least 20 seconds after
powering-on the product.
See section 8 regarding sensor adjustment
Installation: electrical continued…
Power:
6W
Approval EU:
EN 60950, EN 60335
Approval UL:
UL 1310
Input voltage:
100V - 240V~ 50 - 60Hz
Protection class:
II
DIN EN 60730-1: Type 1
Electrical information & approvals: