12
Fig13
View from rear showing solenoid valves link cable fitted
note: additional spade
connectors on one
end of solenoid link
cable
connect other end of
link cable to terminals
of other solenoid
connect one end
of link cable to
terminals of one
solenoid
+
-
solenoid
valve
terminals
o -
Fig12
View from rear showing one
of the solenoid valves
Fig11
Showing overview of electrical installation
< mains power supply in
cable from sensor
(grey)
sensor
solenoid linking cable
(red & black)
cable from
sensor
(red & black)
solenoids
PSU
case
Connection of this product to mains
power supply should be undertaken by a
competent person and should conform to
IEE Wiring Regulations.
A typical example of an installation of a prox-
imity mixer is shown here as a guide.
Orientation & position of solenoids, and PSU
(Power Supply Unit) case can differ from in
-
stallation to installation.
An overview of the electrical wiring is shown
in Fig 11
With the product securely mounted to the panel &
plumbed-in, electrical work can commence.
7
INSTALLATION: ELECTRICAL
First connect the two solenoid valves together using the separate link cable provided. The link cable is
black & red with connectors fitted at both ends. Cable length is 500mm.
Connect the cable to the solenoid valve terminals as shown. Observe the + and – symbols marked on
the solenoid valves, connect the red cables to + & black to -.
Note: one end of this link cable is fitted with additional spade connectors
as shown. These connectors are for attaching the red & black sensor cable.