ID121610
Non-Confidential
4.6.5
Floating-point Default Status Control Register
The FPDSCR register holds the default values for the floating-point status control data. See the
register summary in
Cortex-M4F floating-point system registers
for its attributes.
The bit assignments are:
4.6.6
Enabling the FPU
The FPU is disabled from reset. You must enable it before you can use any floating-point
instructions.
shows an example code sequence for enabling the FPU in both
privileged and user modes. The processor must be in privileged mode to read from and write to
the CPACR.
Example 4-1 Enabling the FPU
; CPACR is located at address 0xE000ED88
LDR.W
R0, =0xE000ED88
; Read CPACR
LDR
R1, [R0]
; Set bits 20-23 to enable CP10 and CP11 coprocessors
ORR
R1, R1, #(0xF << 20)
; Write back the modified value to the CPACR
STR
R1, [R0]; wait for store to complete
DSB
;reset pipeline now the FPU is enabled
ISB
Table 4-54 FPDSCR register bit assignments
Bits
Name
Function
[31:27]
-
Reserved
[26]
AHP
Default value for
FPSCR.AHP
[25]
DN
Default value for
FPSCR.DN
[24]
FZ
Default value for
FPSCR.FZ
[23:22]
RMode
Default value for
FPSCR.RMode
[21:0]
-
Reserved
0
Reserved
31
27 26 25 24 23 22 21
0
0 0 0 0
Reserved
AHP
RMode
DN
FZ