MAGS1 User Guide
3
V1.5 22-1-2016
1. Introduction
1.1. Operating Principle
The measurement is based on the principle of
Faraday‘s law on
electromagnetic induction in which an electric voltage is induced in an
electrically conductive body that moves in a magnetic field. Liquid flows
through a tube in the direction of the magnetic field. Liquid with a certain
minimum electrical conductivity induces a voltage which is detected by two
electrodes located in a 90 degree angle from the magnetic field and the flow
direction.
1.2. Applications
Water / waste
water
Chemical
industry
Food industry
Power
engineering
Agriculture
Effluent
Industry
1.3. Safety Instructions
Please read this manual carefully before using the product.
Keep this manual for future reference. Arkon Flow Systems, s.r.o. will not be liable for any
damage caused by improper use of the product or its accessories.
If the device is used any different way than is specified, the electric protection may be disrupted.
The MAGS1 flow converter - flow-meter must not be mounted in explosive hazardous areas.
1.4. Unpacking the flowmeter
While unpacking the flowmeter, conduct a
visual check of the flowmeter upon receipt to
make sure the product has not been damaged
during transport.
Check the completeness of the package. In
case of any problem, contact the Arkon sales
department without delay.
o
MAGS1 Flowmeter
o
CD-ROM + Manual
Minimum liquid conductivity
>20
s / cm for demineralised cold water.
>5
s / cm for other liquid.
Liquid velocity
min. 0.1 m / sec, max. 10 m / sec.